Acute effects of haemodialysis on central venous and arterial pressure characteristics. (February 2015)
- Record Type:
- Journal Article
- Title:
- Acute effects of haemodialysis on central venous and arterial pressure characteristics. (February 2015)
- Main Title:
- Acute effects of haemodialysis on central venous and arterial pressure characteristics
- Authors:
- Thalhammer, Christoph
Segerer, Stephan
Augustoni, Marlene
Jacomella, Vincenzo
Clemens, Robert K.
Wüthrich, Rudolf P.
Amann‐Vesti, Beatrice R.
Husmann, Marc - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="nep12356-sec-0001" sec-type="section"> <title>Aim</title> <p>Haemodynamic stability of patients during haemodialysis (HD) sessions is of pivotal importance and accurate determination of dry weight remains a challenge. Little information is available about central venous and aortic pressure during dialysis. In this pilot study we used a non‐invasive technique to describe the changes in central venous pressure (CVP) during dialysis.</p> </sec> <sec id="nep12356-sec-0002" sec-type="section"> <title>Methods</title> <p>An ultrasound‐assisted pressure‐manometer was used at the cephalic vein during haemodialysis to quantify CVP. Central aortic pressure changes were assessed as aortic augmentation index and subendocardial viability ratio. Bioimpedance was applied to measure total body water, as well as extracellular and intracellular water before and after HD. Measurements were performed prior during and after 1 and 2 h on HD.</p> </sec> <sec id="nep12356-sec-0003" sec-type="section"> <title>Results</title> <p>Ten patients were included with a median age of 72 years (23–82). Haemodialysis reduced the weight by 2.0 kg, corresponding to a measured decrease in total body water of 1.9 L. The mean CVP showed a significant decrease (9.0–0.8 cmH<sub>2</sub>O; <italic>P</italic> = 0.0005) during dialysis. The significant drop in CVP was found during the first hour (9–2.8 cmH<sub>2</sub>O). Starting and stopping dialysis was<abstract abstract-type="main"> <title>Abstract</title> <sec id="nep12356-sec-0001" sec-type="section"> <title>Aim</title> <p>Haemodynamic stability of patients during haemodialysis (HD) sessions is of pivotal importance and accurate determination of dry weight remains a challenge. Little information is available about central venous and aortic pressure during dialysis. In this pilot study we used a non‐invasive technique to describe the changes in central venous pressure (CVP) during dialysis.</p> </sec> <sec id="nep12356-sec-0002" sec-type="section"> <title>Methods</title> <p>An ultrasound‐assisted pressure‐manometer was used at the cephalic vein during haemodialysis to quantify CVP. Central aortic pressure changes were assessed as aortic augmentation index and subendocardial viability ratio. Bioimpedance was applied to measure total body water, as well as extracellular and intracellular water before and after HD. Measurements were performed prior during and after 1 and 2 h on HD.</p> </sec> <sec id="nep12356-sec-0003" sec-type="section"> <title>Results</title> <p>Ten patients were included with a median age of 72 years (23–82). Haemodialysis reduced the weight by 2.0 kg, corresponding to a measured decrease in total body water of 1.9 L. The mean CVP showed a significant decrease (9.0–0.8 cmH<sub>2</sub>O; <italic>P</italic> = 0.0005) during dialysis. The significant drop in CVP was found during the first hour (9–2.8 cmH<sub>2</sub>O). Starting and stopping dialysis was reflected by a reduction of 2.6 cmH<sub>2</sub>O and a rise of 2.8 cmH<sub>2</sub>O (n.s.). Aortic augmentation index decreased from 26.1% to 21.0% (n.s.). Subendocardial viability ratio increased from 126% to 156% (<italic>P</italic> &lt; 0.05) during HD, and decreased to 139% direct after HD (n.s.).</p> </sec> <sec id="nep12356-sec-0004" sec-type="section"> <title>Conclusion</title> <p>This is the first study that illustrates a prominent reduction of CVP during the first hour of haemodialysis. Non‐invasive CVP measurement is feasible during haemodialysis and adds another piece in the puzzle of factors involved in haemodynamic stability.</p> </sec> </abstract> … (more)
- Is Part Of:
- Nephrology. Volume 20:Number 2(2015)
- Journal:
- Nephrology
- Issue:
- Volume 20:Number 2(2015)
- Issue Display:
- Volume 20, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 20
- Issue:
- 2
- Issue Sort Value:
- 2015-0020-0002-0000
- Page Start:
- 91
- Page End:
- 95
- Publication Date:
- 2015-02
- Subjects:
- Nephrology -- Periodicals
Kidneys -- Diseases -- Periodicals
Nephrologists -- Periodicals
616.61
616.61 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/nep.12356 ↗
- Languages:
- English
- ISSNs:
- 1320-5358
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.684400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3587.xml