Clinical Application Evaluation of Two Fourth‐Generation Human Immunodeficiency Virus (HIV) Screening Assays in West China Hospital. Issue 2 (5th May 2014)
- Record Type:
- Journal Article
- Title:
- Clinical Application Evaluation of Two Fourth‐Generation Human Immunodeficiency Virus (HIV) Screening Assays in West China Hospital. Issue 2 (5th May 2014)
- Main Title:
- Clinical Application Evaluation of Two Fourth‐Generation Human Immunodeficiency Virus (HIV) Screening Assays in West China Hospital
- Authors:
- Liu, Yongming
Li, Dongdong
Wang, Tingting
Yan, Kening
Zhu, Siyuan
Yang, Tingfu
Luo, Lan
Tao, Chuanmin - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21743-sec-0010" sec-type="section"> <title>Background</title> <p>Fourth‐generation human immunodeficiency virus (HIV) screening assays have been used in many laboratories. The Elecsys® HIV combi PT assay is a new kind of fourth‐generation HIV screening assay developed to allow earlier detection of seroconversion.</p> </sec> <sec id="jcla21743-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 271, 845 routine specimens were detected using the Elecsys® HIV combi assay and Elecsys® HIV combi PT assay from September 2010 to December 2012 in a large university hospital. Repeatedly, reactive screening samples were confirmed according to recommended confirmatory algorithms.</p> </sec> <sec id="jcla21743-sec-0030" sec-type="section"> <title>Results</title> <p>The false‐positive rate and positive predictive value (PPV) of two assays are 0.08 and 78.35%, respectively, for the Elecsys® HIV combi assay and 0.07 and 82.21% for the Elecsys® HIV combi PT assay. Ninety‐four percent cases with cutoff index ratio &lt;15.0 were false‐positive. When we set the specificity as 95.0 and 99.0%, PPV could increase to 98.7, 99.6, 98.8, and 99.7%, and sensitivity reduced to 99.2, 98.4, 98.5, and 96.8% for the Elecsys® HIV combi assay and the Elecsys® HIV combi PT assay, respectively.</p> </sec> <sec id="jcla21743-sec-0040" sec-type="section"> <title>Conclusions</title> <p>The Elecsys®<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21743-sec-0010" sec-type="section"> <title>Background</title> <p>Fourth‐generation human immunodeficiency virus (HIV) screening assays have been used in many laboratories. The Elecsys® HIV combi PT assay is a new kind of fourth‐generation HIV screening assay developed to allow earlier detection of seroconversion.</p> </sec> <sec id="jcla21743-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 271, 845 routine specimens were detected using the Elecsys® HIV combi assay and Elecsys® HIV combi PT assay from September 2010 to December 2012 in a large university hospital. Repeatedly, reactive screening samples were confirmed according to recommended confirmatory algorithms.</p> </sec> <sec id="jcla21743-sec-0030" sec-type="section"> <title>Results</title> <p>The false‐positive rate and positive predictive value (PPV) of two assays are 0.08 and 78.35%, respectively, for the Elecsys® HIV combi assay and 0.07 and 82.21% for the Elecsys® HIV combi PT assay. Ninety‐four percent cases with cutoff index ratio &lt;15.0 were false‐positive. When we set the specificity as 95.0 and 99.0%, PPV could increase to 98.7, 99.6, 98.8, and 99.7%, and sensitivity reduced to 99.2, 98.4, 98.5, and 96.8% for the Elecsys® HIV combi assay and the Elecsys® HIV combi PT assay, respectively.</p> </sec> <sec id="jcla21743-sec-0040" sec-type="section"> <title>Conclusions</title> <p>The Elecsys® HIV combi PT assay shows a better performance in specificity than the Elecsys® HIV combi assay. Most weakly reactive results were false‐positive, this means it still need to be improved and it will need laboratory personnel to communicate with the clinical doctor and patients more properly about the result of the assay.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 29:Issue 2(2015)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 29:Issue 2(2015)
- Issue Display:
- Volume 29, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2015-0029-0002-0000
- Page Start:
- 146
- Page End:
- 152
- Publication Date:
- 2014-05-05
- Subjects:
- Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21743 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4056.xml