Development of simple equations for effective screening of spurious hemolysis in whole‐blood specimens. (12th July 2014)
- Record Type:
- Journal Article
- Title:
- Development of simple equations for effective screening of spurious hemolysis in whole‐blood specimens. (12th July 2014)
- Main Title:
- Development of simple equations for effective screening of spurious hemolysis in whole‐blood specimens
- Authors:
- Lippi, G.
Pavesi, F.
Avanzini, P.
Chetta, F.
Aloe, R.
Pipitone, S. - Abstract:
- <abstract abstract-type="main" id="ijlh12277-abs-0001"> <title>Summary</title> <sec id="ijlh12277-sec-0001" sec-type="section"> <title>Introduction</title> <p>We aimed to identify simple but reliable indices for effective screening of spurious hemolysis in whole‐blood specimens.</p> </sec> <sec id="ijlh12277-sec-0002" sec-type="section"> <title>Methods</title> <p>Thirteen inpatient whole‐blood samples were divided in two aliquots. The former was left untreated, whereas the latter was mechanically hemolyzed by forced aspiration with an insulin syringe. All aliquots were tested on Siemens Advia 2120 and Sysmex XE‐2100. The hemolysis index (HI) was also assessed in centrifuged plasma.</p> </sec> <sec id="ijlh12277-sec-0003" sec-type="section"> <title>Results</title> <p>The mechanical hemolysis generated a 4–40% decrease in red blood cells (RBCs). A statistically significant decrease was observed for hematocrit (Ht) and mean corpuscular volume (MCV), whereas mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and platelet count were increased. The values of hemoglobin (Hb) and white blood cells remained substantially unchanged. Two specific equations ([Ht/Hb] × √MCV and [Ht/Hb] × 100) were developed. Both equations displayed an area under the curve of ≥0.99 for identifying spurious hemolysis, much greater than that of both RBC ghosts and immature platelet fraction. A highly significant correlation was also observed between results of these equations and<abstract abstract-type="main" id="ijlh12277-abs-0001"> <title>Summary</title> <sec id="ijlh12277-sec-0001" sec-type="section"> <title>Introduction</title> <p>We aimed to identify simple but reliable indices for effective screening of spurious hemolysis in whole‐blood specimens.</p> </sec> <sec id="ijlh12277-sec-0002" sec-type="section"> <title>Methods</title> <p>Thirteen inpatient whole‐blood samples were divided in two aliquots. The former was left untreated, whereas the latter was mechanically hemolyzed by forced aspiration with an insulin syringe. All aliquots were tested on Siemens Advia 2120 and Sysmex XE‐2100. The hemolysis index (HI) was also assessed in centrifuged plasma.</p> </sec> <sec id="ijlh12277-sec-0003" sec-type="section"> <title>Results</title> <p>The mechanical hemolysis generated a 4–40% decrease in red blood cells (RBCs). A statistically significant decrease was observed for hematocrit (Ht) and mean corpuscular volume (MCV), whereas mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and platelet count were increased. The values of hemoglobin (Hb) and white blood cells remained substantially unchanged. Two specific equations ([Ht/Hb] × √MCV and [Ht/Hb] × 100) were developed. Both equations displayed an area under the curve of ≥0.99 for identifying spurious hemolysis, much greater than that of both RBC ghosts and immature platelet fraction. A highly significant correlation was also observed between results of these equations and percentage reduction in RBCs or HI increase.</p> </sec> <sec id="ijlh12277-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Provided that these results will be confirmed in further studies, these equations may provide a reliable means for screening spurious hemolysis in whole‐blood samples.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 37:Number 2(2015:Apr.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 37:Number 2(2015:Apr.)
- Issue Display:
- Volume 37, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2015-0037-0002-0000
- Page Start:
- 253
- Page End:
- 258
- Publication Date:
- 2014-07-12
- Subjects:
- Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12277 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2963.xml