The use of 3D power doppler ultrasound in the quantification of blood vessels in uterine fibroids: Feasibility and reproducibility. Issue 3 (11th August 2014)
- Record Type:
- Journal Article
- Title:
- The use of 3D power doppler ultrasound in the quantification of blood vessels in uterine fibroids: Feasibility and reproducibility. Issue 3 (11th August 2014)
- Main Title:
- The use of 3D power doppler ultrasound in the quantification of blood vessels in uterine fibroids: Feasibility and reproducibility
- Authors:
- Nieuwenhuis, Lotte L.
Betjes, Heleen E.
Hehenkamp, Wouter J.K.
Heymans, Martijn W.
Brolmann, Hans A.M.
Huirne, Judith A.F. - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <sec id="jcu22208-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate the interobserver agreement and discriminating value of three‐dimensional power Doppler ultrasound (3D PDUS) in patients with fibroids.</p> </sec> <sec id="jcu22208-sec-0002" sec-type="section"> <title>Methods</title> <p>An observational prospective cohort study in 19 patients with fibroids. 3D PDUS was performed by one examiner and evaluated by three independent examiners in order to evaluate various vascular parameters: vascular index (VI), flow index, and vascular flow index of the fibroid, the vascular capsule and of its highest vascular area, using both manual and automatic contour modes. The intraclass correlation coefficient and discriminating values were calculated. The correlation between VI and volume was studied using Kendall's Tau test.</p> </sec> <sec id="jcu22208-sec-0003" sec-type="section"> <title>Results</title> <p>In the manual contour mode, the VIs of the fibroid and of the vascular capsule had the highest interobserver agreements (intraclass correlation coefficients of 0.89 and 0.87, respectively). Both parameters seem to have good discriminating values, given the large range of these parameters between different fibroids, independent of their volume. The vascularity of the fibroid and capsule was related. VI was not related to the volume of the fibroid.</p> </sec> <sec id="jcu22208-sec-0004" sec-type="section"><abstract abstract-type="main"> <title>ABSTRACT</title> <sec id="jcu22208-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate the interobserver agreement and discriminating value of three‐dimensional power Doppler ultrasound (3D PDUS) in patients with fibroids.</p> </sec> <sec id="jcu22208-sec-0002" sec-type="section"> <title>Methods</title> <p>An observational prospective cohort study in 19 patients with fibroids. 3D PDUS was performed by one examiner and evaluated by three independent examiners in order to evaluate various vascular parameters: vascular index (VI), flow index, and vascular flow index of the fibroid, the vascular capsule and of its highest vascular area, using both manual and automatic contour modes. The intraclass correlation coefficient and discriminating values were calculated. The correlation between VI and volume was studied using Kendall's Tau test.</p> </sec> <sec id="jcu22208-sec-0003" sec-type="section"> <title>Results</title> <p>In the manual contour mode, the VIs of the fibroid and of the vascular capsule had the highest interobserver agreements (intraclass correlation coefficients of 0.89 and 0.87, respectively). Both parameters seem to have good discriminating values, given the large range of these parameters between different fibroids, independent of their volume. The vascularity of the fibroid and capsule was related. VI was not related to the volume of the fibroid.</p> </sec> <sec id="jcu22208-sec-0004" sec-type="section"> <title>Conclusions</title> <p>VI assessed using 3D PDUS is a reproducible parameter in the assessment of fibroid vascularization with discriminating abilities. Additional studies are needed to further evaluate its validity and clinical relevance. © 2014 Wiley Periodicals, Inc. <italic>J Clin Ultrasound</italic><bold>43</bold>:171–178, 2015;</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical ultrasound. Volume 43:Issue 3(2015:Apr.)
- Journal:
- Journal of clinical ultrasound
- Issue:
- Volume 43:Issue 3(2015:Apr.)
- Issue Display:
- Volume 43, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 3
- Issue Sort Value:
- 2015-0043-0003-0000
- Page Start:
- 171
- Page End:
- 178
- Publication Date:
- 2014-08-11
- Subjects:
- Ultrasonics in medicine -- Periodicals
616.07543 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcu.22208 ↗
- Languages:
- English
- ISSNs:
- 0091-2751
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.791000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3858.xml