The Figure‐of‐Eight Artifact in the Echocardiographic Assessment of Percutaneous Disc Occluders: Impact of Imaging Depth and Device Type. Issue 3 (22nd July 2014)
- Record Type:
- Journal Article
- Title:
- The Figure‐of‐Eight Artifact in the Echocardiographic Assessment of Percutaneous Disc Occluders: Impact of Imaging Depth and Device Type. Issue 3 (22nd July 2014)
- Main Title:
- The Figure‐of‐Eight Artifact in the Echocardiographic Assessment of Percutaneous Disc Occluders: Impact of Imaging Depth and Device Type
- Authors:
- Bertrand, Philippe B.
Grieten, Lars
Smeets, Christophe J.P.
Verbrugge, Frederik H.
Mullens, Wilfried
Vrolix, Mathias
Rivero‐Ayerza, Maximo
Verhaert, David
Vandervoort, Pieter M. - Abstract:
- <abstract abstract-type="main" id="echo12685-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12685-sec-0001" sec-type="section"> <title>Purpose</title> <p>Echocardiography is increasingly important in the guidance and follow‐up of percutaneous transcatheter device closures. It was recently shown that the Amplatzer left atrial appendage occluder frequently presents as a figure‐of‐eight artifact due to interaction of device mesh and ultrasound waves. It remains unknown whether this can be translated to other types of disc occluders. Furthermore, the morphology of this figure‐of‐eight artifact appears to be different in the transesophageal and transthoracic image of the same device. The aim of this study was to evaluate the echocardiographic appearance of different types of disc occluders, and to clarify differences in morphology of the figure‐of‐eight artifact.</p> </sec> <sec id="echo12685-sec-0002" sec-type="section"> <title>Methods</title> <p>A mathematical model of an epitrochoid curve was used for numerical simulation of disc occluder appearance at various imaging depths. In addition, an in vitro setup was used for echocardiographic analysis of different types of disc occluders at adjustable imaging depth and position.</p> </sec> <sec id="echo12685-sec-0003" sec-type="section"> <title>Results</title> <p>Mathematically, decreasing the imaging depth resulted in a more asymmetric figure‐of‐eight, i.e. with small upper part and wide lower part.<abstract abstract-type="main" id="echo12685-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12685-sec-0001" sec-type="section"> <title>Purpose</title> <p>Echocardiography is increasingly important in the guidance and follow‐up of percutaneous transcatheter device closures. It was recently shown that the Amplatzer left atrial appendage occluder frequently presents as a figure‐of‐eight artifact due to interaction of device mesh and ultrasound waves. It remains unknown whether this can be translated to other types of disc occluders. Furthermore, the morphology of this figure‐of‐eight artifact appears to be different in the transesophageal and transthoracic image of the same device. The aim of this study was to evaluate the echocardiographic appearance of different types of disc occluders, and to clarify differences in morphology of the figure‐of‐eight artifact.</p> </sec> <sec id="echo12685-sec-0002" sec-type="section"> <title>Methods</title> <p>A mathematical model of an epitrochoid curve was used for numerical simulation of disc occluder appearance at various imaging depths. In addition, an in vitro setup was used for echocardiographic analysis of different types of disc occluders at adjustable imaging depth and position.</p> </sec> <sec id="echo12685-sec-0003" sec-type="section"> <title>Results</title> <p>Mathematically, decreasing the imaging depth resulted in a more asymmetric figure‐of‐eight, i.e. with small upper part and wide lower part. In vitro results were in close agreement with the mathematical results. In addition, in vitro a figure‐of‐eight artifact was obtained in all different types of disc occluder devices.</p> </sec> <sec id="echo12685-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Different types of percutaneous disc occluders all present as a figure‐of‐eight artifact on echocardiography when imaged from a coronal imaging position. The morphology of the artifact depends on the imaging depth, with a more asymmetric figure‐of‐eight morphology at smaller probe‐to‐device distance. This clarifies the differences observed between transesophageal and transthoracic imaging.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 32:Issue 3(2015:Mar.)
- Journal:
- Echocardiography
- Issue:
- Volume 32:Issue 3(2015:Mar.)
- Issue Display:
- Volume 32, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2015-0032-0003-0000
- Page Start:
- 557
- Page End:
- 564
- Publication Date:
- 2014-07-22
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12685 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3877.xml