Early loading of 6‐mm‐short implants with a moderately rough surface supporting single crowns – a prospective 5‐year cohort study. Issue 4 (15th April 2014)
- Record Type:
- Journal Article
- Title:
- Early loading of 6‐mm‐short implants with a moderately rough surface supporting single crowns – a prospective 5‐year cohort study. Issue 4 (15th April 2014)
- Main Title:
- Early loading of 6‐mm‐short implants with a moderately rough surface supporting single crowns – a prospective 5‐year cohort study
- Authors:
- Rossi, Fabio
Lang, Niklaus P.
Ricci, Emanuele
Ferraioli, Lorenzo
Marchetti, Claudio
Botticelli, Daniele - Abstract:
- <abstract abstract-type="main" id="clr12409-abs-0001"> <title>Abstract</title> <sec id="clr12409-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate prospectively the clinical and radiographic outcomes after 5 years of early loading of 6‐mm implants with a moderately rough (SLActive<sup>®</sup>) surface supporting single crowns in the posterior regions.</p> </sec> <sec id="clr12409-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Thirty‐five consecutive patients received 40 SLActive<sup>®</sup> (Straumann) 6‐mm implants with a diameter of 4.1 mm (<italic>n</italic> = 19) or 4.8 mm (<italic>n</italic> = 21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35 Ncm after 6 weeks of healing, and single porcelain fuse to metal crowns was cemented within 1 week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5 years after loading. The clinical crown/implant ratio was calculated as well.</p> </sec> <sec id="clr12409-sec-0003" sec-type="section"> <title>Results</title> <p>Two of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5‐year follow‐up period. A mean marginal bone loss of 0.7 ± 0.6 mm was found after 5 years of function. The clinical crown/implant ratio increased with time<abstract abstract-type="main" id="clr12409-abs-0001"> <title>Abstract</title> <sec id="clr12409-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate prospectively the clinical and radiographic outcomes after 5 years of early loading of 6‐mm implants with a moderately rough (SLActive<sup>®</sup>) surface supporting single crowns in the posterior regions.</p> </sec> <sec id="clr12409-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Thirty‐five consecutive patients received 40 SLActive<sup>®</sup> (Straumann) 6‐mm implants with a diameter of 4.1 mm (<italic>n</italic> = 19) or 4.8 mm (<italic>n</italic> = 21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35 Ncm after 6 weeks of healing, and single porcelain fuse to metal crowns was cemented within 1 week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5 years after loading. The clinical crown/implant ratio was calculated as well.</p> </sec> <sec id="clr12409-sec-0003" sec-type="section"> <title>Results</title> <p>Two of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5‐year follow‐up period. A mean marginal bone loss of 0.7 ± 0.6 mm was found after 5 years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5 years of loading.</p> </sec> <sec id="clr12409-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Six millimeter implants with a SLActive<sup>®</sup> moderately rough surface supporting single crowns in the posterior region and loaded after 6–7 weeks maintained full function for at least 5 year with low marginal bone resorption.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 26:Issue 4(2015:Apr.)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 26:Issue 4(2015:Apr.)
- Issue Display:
- Volume 26, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2015-0026-0004-0000
- Page Start:
- 471
- Page End:
- 477
- Publication Date:
- 2014-04-15
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12409 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3420.xml