Real‐world variability in dabigatran levels in patients with atrial fibrillation. (28th January 2015)
- Record Type:
- Journal Article
- Title:
- Real‐world variability in dabigatran levels in patients with atrial fibrillation. (28th January 2015)
- Main Title:
- Real‐world variability in dabigatran levels in patients with atrial fibrillation
- Authors:
- Chan, N. C.
Coppens, M.
Hirsh, J.
Ginsberg, J. S.
Weitz, J. I.
Vanassche, T.
Douketis, J. D.
Schulman, S.
Eikelboom, J. W. - Abstract:
- <abstract abstract-type="main" id="jth12823-abs-0001"> <title>Summary</title> <sec id="jth12823-sec-0001" sec-type="section"> <title>Background</title> <p>In clinical practice, physicians are given the choice of selecting one of two dabigatran doses based on patient characteristics, with the lower dose typically used in patients at a higher risk of bleeding.</p> </sec> <sec id="jth12823-sec-0002" sec-type="section"> <title>Objectives</title> <p>The objectives of the study were to (i) estimate the inter‐ and intra‐patient variability in dabigatran levels with 110 mg (DE110) and 150 mg (DE150) doses, (ii) examine the effect of physicians' dose selection on levels in DE110 and DE150 subgroups, and (iii) explore whether a single trough measurement identifies patients with extreme levels on subsequent visits.</p> </sec> <sec id="jth12823-sec-0003" sec-type="section"> <title>Methods</title> <p>In this prospective observational study of 100 patients with atrial fibrillation (AF), peak and trough levels of dabigatran were measured with the Hemoclot<sup>®</sup> assay at baseline and every 2 months thereafter (maximum four visits).</p> </sec> <sec id="jth12823-sec-0004" sec-type="section"> <title>Results</title> <p>Inter‐patient variability in dabigatran levels (geometric coefficient of variation [gCV], 51–64%) was greater than intra‐patient variability (gCV, 32–40%). Similar medians and distributions of levels were observed in DE110 and DE150 subgroups. Patients receiving DE110 were<abstract abstract-type="main" id="jth12823-abs-0001"> <title>Summary</title> <sec id="jth12823-sec-0001" sec-type="section"> <title>Background</title> <p>In clinical practice, physicians are given the choice of selecting one of two dabigatran doses based on patient characteristics, with the lower dose typically used in patients at a higher risk of bleeding.</p> </sec> <sec id="jth12823-sec-0002" sec-type="section"> <title>Objectives</title> <p>The objectives of the study were to (i) estimate the inter‐ and intra‐patient variability in dabigatran levels with 110 mg (DE110) and 150 mg (DE150) doses, (ii) examine the effect of physicians' dose selection on levels in DE110 and DE150 subgroups, and (iii) explore whether a single trough measurement identifies patients with extreme levels on subsequent visits.</p> </sec> <sec id="jth12823-sec-0003" sec-type="section"> <title>Methods</title> <p>In this prospective observational study of 100 patients with atrial fibrillation (AF), peak and trough levels of dabigatran were measured with the Hemoclot<sup>®</sup> assay at baseline and every 2 months thereafter (maximum four visits).</p> </sec> <sec id="jth12823-sec-0004" sec-type="section"> <title>Results</title> <p>Inter‐patient variability in dabigatran levels (geometric coefficient of variation [gCV], 51–64%) was greater than intra‐patient variability (gCV, 32–40%). Similar medians and distributions of levels were observed in DE110 and DE150 subgroups. Patients receiving DE110 were older, had lower renal function and weighed less than those receiving DE150. Up to 40% of patients whose trough levels were in the upper extremes, and up to 80% of patients whose trough levels were in the lower extremes at baseline, showed subsequent levels that fell in the middle quartiles.</p> </sec> <sec id="jth12823-sec-0005" sec-type="section"> <title>Conclusions</title> <p>Our data support the practice of selecting the dabigatran dose based upon clinical characteristics because it results in similar levels of drug exposure in patients given DE110 or DE150. They do not support the concept that a single Hemoclot<sup>®</sup> measurement reliably identifies patients with consistently high or low values.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of thrombosis and haemostasis. Volume 13:Number 3(2015:Mar.)
- Journal:
- Journal of thrombosis and haemostasis
- Issue:
- Volume 13:Number 3(2015:Mar.)
- Issue Display:
- Volume 13, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 13
- Issue:
- 3
- Issue Sort Value:
- 2015-0013-0003-0000
- Page Start:
- 353
- Page End:
- 359
- Publication Date:
- 2015-01-28
- Subjects:
- Thrombosis -- Periodicals
Hemostasis -- Periodicals
Blood coagulation disorders -- Periodicals
616.1 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1538-7836 ↗
http://www.blackwellpublishing.com/journals/jth ↗
https://www.sciencedirect.com/journal/journal-of-thrombosis-and-haemostasis ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jth.12823 ↗
- Languages:
- English
- ISSNs:
- 1538-7933
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.345000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3462.xml