Two‐piece zirconia implants supporting all‐ceramic crowns: A prospective clinical study. Issue 4 (26th March 2014)
- Record Type:
- Journal Article
- Title:
- Two‐piece zirconia implants supporting all‐ceramic crowns: A prospective clinical study. Issue 4 (26th March 2014)
- Main Title:
- Two‐piece zirconia implants supporting all‐ceramic crowns: A prospective clinical study
- Authors:
- Cionca, Norbert
Müller, Nada
Mombelli, Andrea - Abstract:
- <abstract abstract-type="main" id="clr12370-abs-0001"> <title>Abstract</title> <sec id="clr12370-sec-0001" sec-type="section"> <title>Objectives</title> <p>The aim of this prospective clinical study is to evaluate the safety and efficacy of a new all‐ceramic implant system to replace missing teeth in partially edentulous patients.</p> </sec> <sec id="clr12370-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Thirty‐two partially edentulous, systemically healthy patients were treated with 49 two‐piece zirconia implants (ZERAMEX<sup>®</sup> T Implant System). Zirconia abutments were connected with adhesive resin cement. Single‐unit full‐ceramic crowns were cemented. The cases have been followed for 588±174 days after loading (range 369–889 days). All patients have been re‐evaluated 1 year after loading.</p> </sec> <sec id="clr12370-sec-0003" sec-type="section"> <title>Results</title> <p>The cumulative survival rate 1 year after loading was 87% implants. All failures were the result of aseptic loosening, and no implants were lost after the first year. The results of the other cases were good, and the patients were very satisfied. The cumulative soft tissue complication rate was 0%, the cumulative technical complication rate was 4% implants, the cumulative complication rate for bone loss &gt;2 mm was 0%, and the cumulative esthetic complication rate was 0%. Including the data from 20 patients treated with an earlier version of the system, an over‐all 2‐year<abstract abstract-type="main" id="clr12370-abs-0001"> <title>Abstract</title> <sec id="clr12370-sec-0001" sec-type="section"> <title>Objectives</title> <p>The aim of this prospective clinical study is to evaluate the safety and efficacy of a new all‐ceramic implant system to replace missing teeth in partially edentulous patients.</p> </sec> <sec id="clr12370-sec-0002" sec-type="section"> <title>Material and methods</title> <p>Thirty‐two partially edentulous, systemically healthy patients were treated with 49 two‐piece zirconia implants (ZERAMEX<sup>®</sup> T Implant System). Zirconia abutments were connected with adhesive resin cement. Single‐unit full‐ceramic crowns were cemented. The cases have been followed for 588±174 days after loading (range 369–889 days). All patients have been re‐evaluated 1 year after loading.</p> </sec> <sec id="clr12370-sec-0003" sec-type="section"> <title>Results</title> <p>The cumulative survival rate 1 year after loading was 87% implants. All failures were the result of aseptic loosening, and no implants were lost after the first year. The results of the other cases were good, and the patients were very satisfied. The cumulative soft tissue complication rate was 0%, the cumulative technical complication rate was 4% implants, the cumulative complication rate for bone loss &gt;2 mm was 0%, and the cumulative esthetic complication rate was 0%. Including the data from 20 patients treated with an earlier version of the system, an over‐all 2‐year cumulative survival rate of 86% was calculated for a total of 76 two‐piece zirconia implants supporting all‐ceramic crowns in 52 patients.</p> </sec> <sec id="clr12370-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Replacement of single teeth in the posterior area was possible with this new full‐ceramic implant system. Failures were due to aseptic loosening.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 26:Issue 4(2015:Apr.)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 26:Issue 4(2015:Apr.)
- Issue Display:
- Volume 26, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2015-0026-0004-0000
- Page Start:
- 413
- Page End:
- 418
- Publication Date:
- 2014-03-26
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12370 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3420.xml