Validation of a Novel Radiographic Scoring System for Calcinosis Affecting the Hands of Patients With Systemic Sclerosis. Issue 3 (March 2015)
- Record Type:
- Journal Article
- Title:
- Validation of a Novel Radiographic Scoring System for Calcinosis Affecting the Hands of Patients With Systemic Sclerosis. Issue 3 (March 2015)
- Main Title:
- Validation of a Novel Radiographic Scoring System for Calcinosis Affecting the Hands of Patients With Systemic Sclerosis
- Authors:
- Chung, Lorinda
Valenzuela, Antonia
Fiorentino, David
Stevens, Kathryn
Li, Shufeng
Harris, Jonathan
Hutchinson, Charles
Assassi, Shervin
Beretta, Lorenzo
Lakshminarayanan, Santhanam
Rodriguez‐Reyna, Tatiana S.
Denton, Christopher P.
Taillefer, Rebecca G.
Herrick, Ariane L.
Baron, Murray
for the Scleroderma Clinical Trials Consortium Calcinosis Working Group - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="acr22434-sec-0001" sec-type="section"> <title>Objective</title> <p>There are currently no validated outcome measures to assess calcinosis severity in systemic sclerosis (SSc; scleroderma). We sought to develop and validate a novel radiographic scoring system for calcinosis affecting the hands of SSc patients for potential use in future clinical trials.</p> </sec> <sec id="acr22434-sec-0002" sec-type="section"> <title>Methods</title> <p>Following a 1‐hour teleconference training session, 12 investigators (8 rheumatologists, 1 dermatologist, and 3 radiologists) scored 12 hand radiographs in random order using 2 scoring systems (termed "simple" and "complex") and re‐scored 2 randomly assigned radiographs after a minimum of 24 hours. Interrater and intrarater reliability were assessed using a weighted kappa coefficient for the simple system (κ), and an intraclass correlation coefficient (ICC) for the complex system (ICC &lt;0.4 for poor, 0.4–0.7 for moderate, and &gt;0.7 for excellent).</p> </sec> <sec id="acr22434-sec-0003" sec-type="section"> <title>Results</title> <p>Mean time to complete the complex scoring system was significantly longer than the simple scoring system (4.0 versus 0.4 minutes; <italic>P</italic> &lt; 0.0001). Overall interrater reliability for the simple scoring system was poor (κ = 0.39, 95% confidence interval [95% CI] 0.1–0.52) but improved if dichotomized as<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="acr22434-sec-0001" sec-type="section"> <title>Objective</title> <p>There are currently no validated outcome measures to assess calcinosis severity in systemic sclerosis (SSc; scleroderma). We sought to develop and validate a novel radiographic scoring system for calcinosis affecting the hands of SSc patients for potential use in future clinical trials.</p> </sec> <sec id="acr22434-sec-0002" sec-type="section"> <title>Methods</title> <p>Following a 1‐hour teleconference training session, 12 investigators (8 rheumatologists, 1 dermatologist, and 3 radiologists) scored 12 hand radiographs in random order using 2 scoring systems (termed "simple" and "complex") and re‐scored 2 randomly assigned radiographs after a minimum of 24 hours. Interrater and intrarater reliability were assessed using a weighted kappa coefficient for the simple system (κ), and an intraclass correlation coefficient (ICC) for the complex system (ICC &lt;0.4 for poor, 0.4–0.7 for moderate, and &gt;0.7 for excellent).</p> </sec> <sec id="acr22434-sec-0003" sec-type="section"> <title>Results</title> <p>Mean time to complete the complex scoring system was significantly longer than the simple scoring system (4.0 versus 0.4 minutes; <italic>P</italic> &lt; 0.0001). Overall interrater reliability for the simple scoring system was poor (κ = 0.39, 95% confidence interval [95% CI] 0.1–0.52) but improved if dichotomized as mild/moderate versus severe (κ = 0.51, 95% CI 0.26–0.7). Interrater reliability was excellent for the complex scoring system (ICC 0.89, 95% CI 0.86–0.92). Intrarater reliability was moderate for the simple scoring system (κ = 0.67, 95% CI 0.37–0.96) but almost perfect for the complex scoring system (ICC 0.93, 95% CI 0.89–0.97).</p> </sec> <sec id="acr22434-sec-0004" sec-type="section"> <title>Conclusion</title> <p>We developed a novel radiographic scoring system that accounts for the area coverage, density, and anatomic location of calcinosis affecting the hands in patients with SSc. This scoring system is feasible with excellent reliability and should undergo further validation testing for use in clinical trials.</p> </sec> </abstract> … (more)
- Is Part Of:
- Arthritis care & research. Volume 67:Issue 3(2015:Mar.)
- Journal:
- Arthritis care & research
- Issue:
- Volume 67:Issue 3(2015:Mar.)
- Issue Display:
- Volume 67, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 67
- Issue:
- 3
- Issue Sort Value:
- 2015-0067-0003-0000
- Page Start:
- 425
- Page End:
- 430
- Publication Date:
- 2015-03
- Subjects:
- Arthritis -- Periodicals
Rheumatism -- Periodicals
616.72 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2151-4658 ↗
http://www3.interscience.wiley.com/journal/123227259/grouphome/home.html ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acr.22434 ↗
- Languages:
- English
- ISSNs:
- 2151-464X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4273.xml