USE OF HAND‐TO‐HAND MEASUREMENTS FOR BODY COMPOSITION MONITORING IN PATIENTS WITH INACCESSIBLE OR AMPUTATED FEET. Issue 1 (15th September 2014)
- Record Type:
- Journal Article
- Title:
- USE OF HAND‐TO‐HAND MEASUREMENTS FOR BODY COMPOSITION MONITORING IN PATIENTS WITH INACCESSIBLE OR AMPUTATED FEET. Issue 1 (15th September 2014)
- Main Title:
- USE OF HAND‐TO‐HAND MEASUREMENTS FOR BODY COMPOSITION MONITORING IN PATIENTS WITH INACCESSIBLE OR AMPUTATED FEET
- Authors:
- Keane, David F.
Lindley, Elizabeth - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>SUMMARY</title> <sec id="jorc12091-sec-0001" sec-type="section"> <title>Background</title> <p>The body composition monitor (BCM) provides an objective assessment of fluid status, which has been shown to improve outcomes in patients undergoing haemodialysis. The models used by the BCM were developed and validated using standard wrist‐to‐ankle bioimpedance measurements, made between electrodes on the hand and foot. However, in patients with inaccessible or amputated feet it is not possible to use standard electrode configurations.</p> </sec> <sec id="jorc12091-sec-0002" sec-type="section"> <title>Objective</title> <p>To compare hydration measurements made with 'hand‐to‐hand' (H‐H) and 'hand‐to‐foot' (H‐F) electrode configurations in patients with accessible feet or no amputations.</p> </sec> <sec id="jorc12091-sec-0003" sec-type="section"> <title>Methods</title> <p>One hundred and one consecutive patients referred for a BCM measurement were recruited to have H‐H measurements at the same time as the usual H‐F measurement using the same height and weight. Patients with obvious localised oedema were excluded.</p> </sec> <sec id="jorc12091-sec-0004" sec-type="section"> <title>Results</title> <p>Compared with H‐F, H‐H measurements showed a bias of −0.1 L. For 61% of patients the difference between the readings was within 0.5 L; for 81% it was within 1.0 L.</p> </sec> <sec id="jorc12091-sec-0005" sec-type="section"><abstract abstract-type="main" xml:lang="en"> <title>SUMMARY</title> <sec id="jorc12091-sec-0001" sec-type="section"> <title>Background</title> <p>The body composition monitor (BCM) provides an objective assessment of fluid status, which has been shown to improve outcomes in patients undergoing haemodialysis. The models used by the BCM were developed and validated using standard wrist‐to‐ankle bioimpedance measurements, made between electrodes on the hand and foot. However, in patients with inaccessible or amputated feet it is not possible to use standard electrode configurations.</p> </sec> <sec id="jorc12091-sec-0002" sec-type="section"> <title>Objective</title> <p>To compare hydration measurements made with 'hand‐to‐hand' (H‐H) and 'hand‐to‐foot' (H‐F) electrode configurations in patients with accessible feet or no amputations.</p> </sec> <sec id="jorc12091-sec-0003" sec-type="section"> <title>Methods</title> <p>One hundred and one consecutive patients referred for a BCM measurement were recruited to have H‐H measurements at the same time as the usual H‐F measurement using the same height and weight. Patients with obvious localised oedema were excluded.</p> </sec> <sec id="jorc12091-sec-0004" sec-type="section"> <title>Results</title> <p>Compared with H‐F, H‐H measurements showed a bias of −0.1 L. For 61% of patients the difference between the readings was within 0.5 L; for 81% it was within 1.0 L.</p> </sec> <sec id="jorc12091-sec-0005" sec-type="section"> <title>Conclusion</title> <p>The agreement between H‐H and H‐F measurements was close enough to encourage us to use H‐H measurements in patients with inaccessible or amputated feet. Prior to amputation, height and weight are recorded. Target weight (TW) reductions are made gradually when close to normal hydration. Clinically, changes based on H‐H measurements appear to be as appropriate as those using H‐F. The desired hydration at TW can be established and then TW adjusted to maintain this hydration as the flesh weight fluctuates.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of renal care. Volume 41:Issue 1(2015:Mar.)
- Journal:
- Journal of renal care
- Issue:
- Volume 41:Issue 1(2015:Mar.)
- Issue Display:
- Volume 41, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2015-0041-0001-0000
- Page Start:
- 28
- Page End:
- 32
- Publication Date:
- 2014-09-15
- Subjects:
- Kidneys -- Diseases -- Nursing -- Periodicals
Hemodialysis -- Periodicals
Kidney Diseases -- nursing -- Periodicals
Renal Replacement Therapy -- nursing -- Periodicals
616.61 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=715546 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-6686/issues ↗
http://www3.interscience.wiley.com/journal/118902533/home ↗
http://search.ebscohost.com/login.aspx?direct=true&db=rzh&jid=56RH&site=ehost-live ↗
http://onlinelibrary.wiley.com/ ↗
http://www.edtnaerca.org/pages/education/jrc.php ↗ - DOI:
- 10.1111/jorc.12091 ↗
- Languages:
- English
- ISSNs:
- 1755-6678
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5049.450000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3557.xml