Bubble technique for Descemet membrane endothelial keratoplasty tissue preparation in an eye bank: air or liquid?. (27th August 2014)
- Record Type:
- Journal Article
- Title:
- Bubble technique for Descemet membrane endothelial keratoplasty tissue preparation in an eye bank: air or liquid?. (27th August 2014)
- Main Title:
- Bubble technique for Descemet membrane endothelial keratoplasty tissue preparation in an eye bank: air or liquid?
- Authors:
- Ruzza, Alessandro
Parekh, Mohit
Salvalaio, Gianni
Ferrari, Stefano
Camposampiero, Davide
Amoureux, Marie‐Claude
Busin, Massimo
Ponzin, Diego - Abstract:
- <abstract abstract-type="main" id="aos12520-abs-0001"> <title>Abstract</title> <sec id="aos12520-sec-0001" sec-type="section"> <title>Purpose</title> <p>To compare the big‐bubble method using air and liquid as medium of separation for Descemet membrane endothelial keratoplasty (DMEK) lenticule preparation in an eye bank.</p> </sec> <sec id="aos12520-sec-0002" sec-type="section"> <title>Methods</title> <p>Donor corneas (<italic>n</italic> = 20) were immersed in liquid [tissue culture medium (TCM)]. Air and liquid was injected using a 25‐gauge needle in the posterior stroma or as near to the stroma‐Descemet membrane (DM) phase as possible to create a complete bubble of larger diameter. The endothelial cell density and mortality were checked pre‐ and postbubble after deflating the tissue. Four pairs of tissues were used to analyse the intracellular tight junctions and three pairs for histological examination and DNA integrity studies, respectively.</p> </sec> <sec id="aos12520-sec-0003" sec-type="section"> <title>Results</title> <p>The yield obtained using air was 80%, whereas that with liquid was 100%. Single injection was required in six cases; twice in two cases; three and four times in one case each with air bubble, whereas seven cases required single injection; twice in two cases; and thrice in just one case with liquid bubble. The average diameter of the final lenticule was 9.12 (± 1.71) mm for air bubble and 9.78 (± 1.75) mm for liquid bubble with p = 0.4362 (no<abstract abstract-type="main" id="aos12520-abs-0001"> <title>Abstract</title> <sec id="aos12520-sec-0001" sec-type="section"> <title>Purpose</title> <p>To compare the big‐bubble method using air and liquid as medium of separation for Descemet membrane endothelial keratoplasty (DMEK) lenticule preparation in an eye bank.</p> </sec> <sec id="aos12520-sec-0002" sec-type="section"> <title>Methods</title> <p>Donor corneas (<italic>n</italic> = 20) were immersed in liquid [tissue culture medium (TCM)]. Air and liquid was injected using a 25‐gauge needle in the posterior stroma or as near to the stroma‐Descemet membrane (DM) phase as possible to create a complete bubble of larger diameter. The endothelial cell density and mortality were checked pre‐ and postbubble after deflating the tissue. Four pairs of tissues were used to analyse the intracellular tight junctions and three pairs for histological examination and DNA integrity studies, respectively.</p> </sec> <sec id="aos12520-sec-0003" sec-type="section"> <title>Results</title> <p>The yield obtained using air was 80%, whereas that with liquid was 100%. Single injection was required in six cases; twice in two cases; three and four times in one case each with air bubble, whereas seven cases required single injection; twice in two cases; and thrice in just one case with liquid bubble. The average diameter of the final lenticule was 9.12 (± 1.71) mm for air bubble and 9.78 (± 1.75) mm for liquid bubble with p = 0.4362 (no statistical significance). Endothelial cell mortality postbubble preparation was 8.9 (± 12.38) % for air and 6.25 (± 9.57) % for liquid (p = 0.6268).</p> </sec> <sec id="aos12520-sec-0004" sec-type="section"> <title>Conclusions</title> <p>DM and endothelium could be separated exclusively using air or liquid bubble. However, liquid bubble seems to have certain advantages over air such as the generation of yield, larger diameter and higher maintenance of endothelial cell density and integrity.</p> </sec> </abstract> … (more)
- Is Part Of:
- Acta ophthalmologica. Volume 93:Number 2(2015)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 93:Number 2(2015)
- Issue Display:
- Volume 93, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 93
- Issue:
- 2
- Issue Sort Value:
- 2015-0093-0002-0000
- Page Start:
- e129
- Page End:
- e134
- Publication Date:
- 2014-08-27
- Subjects:
- Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.12520 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3348.xml