Arterial cerebral blood volume–weighted functional MRI using pseudocontinuous arterial spin tagging (AVAST). Issue 3 (18th April 2014)
- Record Type:
- Journal Article
- Title:
- Arterial cerebral blood volume–weighted functional MRI using pseudocontinuous arterial spin tagging (AVAST). Issue 3 (18th April 2014)
- Main Title:
- Arterial cerebral blood volume–weighted functional MRI using pseudocontinuous arterial spin tagging (AVAST)
- Authors:
- Jahanian, Hesamoddin
Peltier, Scott
Noll, Douglas C.
Hernandez Garcia, Luis - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25220-sec-0001" sec-type="section"> <title>Purpose</title> <p>Neurovascular regulation, including responses to neural activation that give rise to the blood oxygenation level–dependent (BOLD) effect, occurs mainly at the arterial and arteriolar level. The purpose of this study is to develop a framework for fast imaging of arterial cerebral blood volume (aCBV) signal suitable for functional imaging studies.</p> </sec> <sec id="mrm25220-sec-0002" sec-type="section"> <title>Methods</title> <p>A variant of the pseudocontinuous arterial spin tagging technique was developed in order to achieve a contrast that depends on aCBV with little contamination from perfusion signal by taking advantage of the kinetics of the tag through the vasculature. This technique tailors the tagging duration and repetition time for each subject. The proposed technique, called AVAST, is compared empirically with BOLD imaging and standard (perfusion‐weighted) arterial spin labeling (ASL) technique, in a motor‐visual activation paradigm.</p> </sec> <sec id="mrm25220-sec-0003" sec-type="section"> <title>Results</title> <p>The average Z‐scores in the activated area obtained over all the subjects were 4.25, 5.52, and 7.87 for standard ASL, AVAST, and BOLD techniques, respectively. The aCBV contrast obtained from AVAST provided 80% higher average signal‐to‐noise ratio and 95% higher average contrast‐to‐noise ratio<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25220-sec-0001" sec-type="section"> <title>Purpose</title> <p>Neurovascular regulation, including responses to neural activation that give rise to the blood oxygenation level–dependent (BOLD) effect, occurs mainly at the arterial and arteriolar level. The purpose of this study is to develop a framework for fast imaging of arterial cerebral blood volume (aCBV) signal suitable for functional imaging studies.</p> </sec> <sec id="mrm25220-sec-0002" sec-type="section"> <title>Methods</title> <p>A variant of the pseudocontinuous arterial spin tagging technique was developed in order to achieve a contrast that depends on aCBV with little contamination from perfusion signal by taking advantage of the kinetics of the tag through the vasculature. This technique tailors the tagging duration and repetition time for each subject. The proposed technique, called AVAST, is compared empirically with BOLD imaging and standard (perfusion‐weighted) arterial spin labeling (ASL) technique, in a motor‐visual activation paradigm.</p> </sec> <sec id="mrm25220-sec-0003" sec-type="section"> <title>Results</title> <p>The average Z‐scores in the activated area obtained over all the subjects were 4.25, 5.52, and 7.87 for standard ASL, AVAST, and BOLD techniques, respectively. The aCBV contrast obtained from AVAST provided 80% higher average signal‐to‐noise ratio and 95% higher average contrast‐to‐noise ratio compared with that of the standard ASL measurements.</p> </sec> <sec id="mrm25220-sec-0004" sec-type="section"> <title>Conclusion</title> <p>AVAST exhibits improved activation detection sensitivity and temporal resolution over the standard ASL technique, in functional MRI experiments, while preserving its quantitative nature and statistical advantages. AVAST particularly could be useful in clinical studies of pathological conditions, longitudinal studies of cognitive function, and studies requiring sustained periods of the condition. <bold>Magn Reson Med 73:1053–1064, 2015. © 2014 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 3(2015:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 3(2015:Mar.)
- Issue Display:
- Volume 73, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 3
- Issue Sort Value:
- 2015-0073-0003-0000
- Page Start:
- 1053
- Page End:
- 1064
- Publication Date:
- 2014-04-18
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25220 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3783.xml