Position of Edwards SAPIEN transcatheter valve in the aortic root in relation with the coronary ostia. Issue 3 (12th November 2014)
- Record Type:
- Journal Article
- Title:
- Position of Edwards SAPIEN transcatheter valve in the aortic root in relation with the coronary ostia. Issue 3 (12th November 2014)
- Main Title:
- Position of Edwards SAPIEN transcatheter valve in the aortic root in relation with the coronary ostia
- Authors:
- Katsanos, Spyridon
Debonnaire, Philippe
van der Kley, Frank
van Rosendael, Philippe
Joyce, Emer
de Graaf, Michiel A.
Schalij, Martin J.
Scholte, Arthur J.H.A.
Bax, Jeroen J.
Ajmone Marsan, Nina
Delgado, Victoria - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25718-sec-0001" sec-type="section"> <title>Objectives</title> <p>To determine the implications of stable coverage of the coronary ostia by the Edwards SAPIEN valve frame in terms of myocardial ischemia and subsequent percutaneous coronary intervention (PCI), following transcatheter aortic valve implantation (TAVI).</p> </sec> <sec id="ccd25718-sec-0002" sec-type="section"> <title>Background</title> <p>Edwards SAPIEN frame is frequently deployed relatively higher than recommended and may overlap the coronary ostia.</p> </sec> <sec id="ccd25718-sec-0003" sec-type="section"> <title>Methods</title> <p>A total of 142 patients (age 81 ± 7 years, male 49%) treated with Edwards SAPIEN valve and with multi‐detector row computed tomography at 1 month follow‐up were evaluated. The position of the frame in relation to the coronary ostia was assessed. Levels of troponin T were measured 12–24 hr after TAVI. PCI events at follow‐up were recorded.</p> </sec> <sec id="ccd25718-sec-0004" sec-type="section"> <title>Results</title> <p>The left coronary ostium was fully covered in three (2.1%) patients and the right coronary ostium in 11 (7.7%). There were no differences in troponin T levels between patients with fully covered ostia versus patients with partly or non‐covered ostia (0.24 (0.13–0.50) μg/L versus 0.35 (0.15–0.55) μg/L, respectively; <italic>P</italic> = 0.377). At 30 ± 15 months follow<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25718-sec-0001" sec-type="section"> <title>Objectives</title> <p>To determine the implications of stable coverage of the coronary ostia by the Edwards SAPIEN valve frame in terms of myocardial ischemia and subsequent percutaneous coronary intervention (PCI), following transcatheter aortic valve implantation (TAVI).</p> </sec> <sec id="ccd25718-sec-0002" sec-type="section"> <title>Background</title> <p>Edwards SAPIEN frame is frequently deployed relatively higher than recommended and may overlap the coronary ostia.</p> </sec> <sec id="ccd25718-sec-0003" sec-type="section"> <title>Methods</title> <p>A total of 142 patients (age 81 ± 7 years, male 49%) treated with Edwards SAPIEN valve and with multi‐detector row computed tomography at 1 month follow‐up were evaluated. The position of the frame in relation to the coronary ostia was assessed. Levels of troponin T were measured 12–24 hr after TAVI. PCI events at follow‐up were recorded.</p> </sec> <sec id="ccd25718-sec-0004" sec-type="section"> <title>Results</title> <p>The left coronary ostium was fully covered in three (2.1%) patients and the right coronary ostium in 11 (7.7%). There were no differences in troponin T levels between patients with fully covered ostia versus patients with partly or non‐covered ostia (0.24 (0.13–0.50) μg/L versus 0.35 (0.15–0.55) μg/L, respectively; <italic>P</italic> = 0.377). At 30 ± 15 months follow up, 10 (7%) patients underwent successful PCI. Rate of subsequent PCI was similar between patients with any covered ostium and patients with non‐covered ostia [4 (7.8%) vs. 6 (6.5%), <italic>P</italic> = 0.780, respectively].</p> </sec> <sec id="ccd25718-sec-0005" sec-type="section"> <title>Conclusions</title> <p>Full overlap of the coronary ostia by Edwards SAPIEN frame is infrequent and in most cases does not limit subsequent PCI. <related-article related-article-type="source" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink">© 2014 Wiley Periodicals, Inc.</related-article></p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 85:Issue 3(2015:Feb. 15)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 85:Issue 3(2015:Feb. 15)
- Issue Display:
- Volume 85, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 85
- Issue:
- 3
- Issue Sort Value:
- 2015-0085-0003-0000
- Page Start:
- 480
- Page End:
- 487
- Publication Date:
- 2014-11-12
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25718 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3447.xml