Comparison of acute elastic recoil between the SAPIEN‐XT and SAPIEN valves in transfemoral–transcatheter aortic valve replacement. Issue 3 (13th November 2014)
- Record Type:
- Journal Article
- Title:
- Comparison of acute elastic recoil between the SAPIEN‐XT and SAPIEN valves in transfemoral–transcatheter aortic valve replacement. Issue 3 (13th November 2014)
- Main Title:
- Comparison of acute elastic recoil between the SAPIEN‐XT and SAPIEN valves in transfemoral–transcatheter aortic valve replacement
- Authors:
- Garg, Aatish
Parashar, Akhil
Agarwal, Shikhar
Aksoy, Olcay
Hammadah, Muhammad
Poddar, Kanhaiya Lal
Puri, Rishi
Svensson, Lars G.
Krishnaswamy, Amar
Tuzcu, E. Murat
Kapadia, Samir R. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25717-sec-0001" sec-type="section"> <title>Background</title> <p>The SAPIEN‐XT is a newer generation balloon‐expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves.</p> </sec> <sec id="ccd25717-sec-0002" sec-type="section"> <title>Methods</title> <p>All patients who underwent transfemoral–transcatheter aortic valve replacement using the SAPIEN‐XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine‐angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) − (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group.</p> </sec> <sec id="ccd25717-sec-0003" sec-type="section"> <title>Results</title> <p>Among the 23 mm valves, the mean (standard deviation—SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (<italic>P</italic> = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (<italic>P</italic> = 0.01). Multivariable linear regression analysis<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25717-sec-0001" sec-type="section"> <title>Background</title> <p>The SAPIEN‐XT is a newer generation balloon‐expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves.</p> </sec> <sec id="ccd25717-sec-0002" sec-type="section"> <title>Methods</title> <p>All patients who underwent transfemoral–transcatheter aortic valve replacement using the SAPIEN‐XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine‐angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) − (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group.</p> </sec> <sec id="ccd25717-sec-0003" sec-type="section"> <title>Results</title> <p>Among the 23 mm valves, the mean (standard deviation—SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (<italic>P</italic> = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (<italic>P</italic> = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69–2.17), <italic>P</italic> &lt; 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (<italic>P</italic> = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (<italic>P</italic> = 0.78).</p> </sec> <sec id="ccd25717-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 85:Issue 3(2015:Feb. 15)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 85:Issue 3(2015:Feb. 15)
- Issue Display:
- Volume 85, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 85
- Issue:
- 3
- Issue Sort Value:
- 2015-0085-0003-0000
- Page Start:
- 490
- Page End:
- 496
- Publication Date:
- 2014-11-13
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25717 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3446.xml