Intra‐operative assessment of pulmonary artery pressure by transoesophageal echocardiography1. (10th November 2014)
- Record Type:
- Journal Article
- Title:
- Intra‐operative assessment of pulmonary artery pressure by transoesophageal echocardiography1. (10th November 2014)
- Main Title:
- Intra‐operative assessment of pulmonary artery pressure by transoesophageal echocardiography1
- Authors:
- Soliman, D.
Bolliger, D.
Skarvan, K.
Kaufmann, B. A.
Lurati Buse, G.
Seeberger, M. D. - Abstract:
- <abstract abstract-type="main" id="anae12920-abs-0001"> <title>Summary</title> <p>The clinical value of the estimation of systolic pulmonary artery pressure, based on Doppler assessment of peak tricuspid regurgitant velocity using transoesophageal echocardiography, is unclear. We studied 109 patients to evaluate the feasibility of obtaining adequate Doppler recordings, and compared Doppler estimates with values measured using a pulmonary artery catheter in a subset of 33 patients. Tricuspid regurgitation was evaluated at the mid‐oesophageal level at 0–120° using Doppler echocardiography. A Doppler signal was defined as adequate if there was a ≤ 20° alignment and a full envelope. Doppler estimates of systolic pulmonary artery pressure within 10 mmHg and 15% of the value recorded with the pulmonary artery catheter were considered to be in sufficient agreement. Adequate Doppler signals were obtained in 64/109 (59%) patients before and 54/103 (52%) after surgery. Doppler estimates by transoesophageal echocardiography were within 10 mmHg and 15% of values recorded with the pulmonary artery catheter in 28/33 (75%) patients and 22/31 (55%) patients, respectively. In 7 (21%) patients, the echocardiographic Doppler measurement exceeded the measured systolic pulmonary artery pressure by more than 30%. Our study indicates that estimation of the systolic pulmonary artery pressure using transoesophageal Doppler echocardiography is not a reliable and clinically useful method in<abstract abstract-type="main" id="anae12920-abs-0001"> <title>Summary</title> <p>The clinical value of the estimation of systolic pulmonary artery pressure, based on Doppler assessment of peak tricuspid regurgitant velocity using transoesophageal echocardiography, is unclear. We studied 109 patients to evaluate the feasibility of obtaining adequate Doppler recordings, and compared Doppler estimates with values measured using a pulmonary artery catheter in a subset of 33 patients. Tricuspid regurgitation was evaluated at the mid‐oesophageal level at 0–120° using Doppler echocardiography. A Doppler signal was defined as adequate if there was a ≤ 20° alignment and a full envelope. Doppler estimates of systolic pulmonary artery pressure within 10 mmHg and 15% of the value recorded with the pulmonary artery catheter were considered to be in sufficient agreement. Adequate Doppler signals were obtained in 64/109 (59%) patients before and 54/103 (52%) after surgery. Doppler estimates by transoesophageal echocardiography were within 10 mmHg and 15% of values recorded with the pulmonary artery catheter in 28/33 (75%) patients and 22/31 (55%) patients, respectively. In 7 (21%) patients, the echocardiographic Doppler measurement exceeded the measured systolic pulmonary artery pressure by more than 30%. Our study indicates that estimation of the systolic pulmonary artery pressure using transoesophageal Doppler echocardiography is not a reliable and clinically useful method in anaesthetised patients undergoing mechanical ventilation.</p> </abstract> … (more)
- Is Part Of:
- Anaesthesia. Volume 70:Number 3(2015:Mar.)
- Journal:
- Anaesthesia
- Issue:
- Volume 70:Number 3(2015:Mar.)
- Issue Display:
- Volume 70, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 70
- Issue:
- 3
- Issue Sort Value:
- 2015-0070-0003-0000
- Page Start:
- 264
- Page End:
- 271
- Publication Date:
- 2014-11-10
- Subjects:
- Anesthesia -- Periodicals
617.96 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.aagbi.org/publications ↗ - DOI:
- 10.1111/anae.12920 ↗
- Languages:
- English
- ISSNs:
- 0003-2409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3118.xml