Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy. (29th October 2014)
- Record Type:
- Journal Article
- Title:
- Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy. (29th October 2014)
- Main Title:
- Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
- Authors:
- DÖRING, MICHAEL
SOMMER, PHILIPP
ROLF, SASCHA
LUCAS, JOHANNES
BREITHARDT, OLE A.
HINDRICKS, GERHARD
RICHTER, SERGIO - Abstract:
- <abstract abstract-type="main"> <title>Electromagnetic Navigation for CRT Implantation</title> <sec id="jce12550-sec-0010" sec-type="section"> <title>Introduction</title> <p>Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation.</p> </sec> <sec id="jce12550-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056)<abstract abstract-type="main"> <title>Electromagnetic Navigation for CRT Implantation</title> <sec id="jce12550-sec-0010" sec-type="section"> <title>Introduction</title> <p>Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation.</p> </sec> <sec id="jce12550-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm<sup>2</sup>. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm<sup>2</sup>, respectively (P = 0.044 ).</p> </sec> <sec id="jce12550-sec-0030" sec-type="section"> <title>Conclusion</title> <p>Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 26:Number 2(2015:Feb.)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 26:Number 2(2015:Feb.)
- Issue Display:
- Volume 26, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 26
- Issue:
- 2
- Issue Sort Value:
- 2015-0026-0002-0000
- Page Start:
- 167
- Page End:
- 175
- Publication Date:
- 2014-10-29
- Subjects:
- Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.12550 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4311.xml