Analysis of inflammatory cytokines in human blood, breath condensate, and urine using a multiplex immunoassay platform. (February 2015)
- Record Type:
- Journal Article
- Title:
- Analysis of inflammatory cytokines in human blood, breath condensate, and urine using a multiplex immunoassay platform. (February 2015)
- Main Title:
- Analysis of inflammatory cytokines in human blood, breath condensate, and urine using a multiplex immunoassay platform
- Authors:
- Stiegel, Matthew A.
Pleil, Joachim D.
Sobus, Jon R.
Morgan, Marsha K.
Madden, Michael C. - Abstract:
- <abstract> <title>Abstract</title> <p>A change in the expression of cytokines in human biological media indicates an inflammatory response to external stressors and reflects an early step along the adverse outcome pathway (AOP) for various health endpoints. To characterize and interpret this inflammatory response, methodology was developed for measuring a suite of 10 different cytokines in human blood, exhaled breath condensate (EBC), and urine using an electrochemiluminescent multiplex Th1/Th2 cytokine immunoassay platform. Measurement distributions and correlations for eight interleukins (IL) (1β, 2, 4, 5, 8, 10, 12p70 and 13), interferon-γ (IFN-γ), and tumor necrosis factor-α (TNF-α) were evaluated using 90 blood plasma, 77 EBC, and 400 urine samples collected from nominally healthy adults subjects in North Carolina in 2008–2012. The <italic>in vivo</italic> results show that there is sufficient sensitivity for characterizing all 10 cytokines at levels of 0.05–0.10 ρg/ml with a dynamic range up to 100 ng/ml across all three of these biological media. The measured <italic>in vivo</italic> results also show that the duplicate analysis of blood, EBC and urine samples have average estimated fold ranges of 2.21, 3.49, and 2.50, respectively, which are similar to the mean estimated fold range (2.88) for the lowest concentration (0.610 ρg/ml) from a series of spiked control samples; the cytokine method can be used for all three biological media. Nine out of the 10 cytokines<abstract> <title>Abstract</title> <p>A change in the expression of cytokines in human biological media indicates an inflammatory response to external stressors and reflects an early step along the adverse outcome pathway (AOP) for various health endpoints. To characterize and interpret this inflammatory response, methodology was developed for measuring a suite of 10 different cytokines in human blood, exhaled breath condensate (EBC), and urine using an electrochemiluminescent multiplex Th1/Th2 cytokine immunoassay platform. Measurement distributions and correlations for eight interleukins (IL) (1β, 2, 4, 5, 8, 10, 12p70 and 13), interferon-γ (IFN-γ), and tumor necrosis factor-α (TNF-α) were evaluated using 90 blood plasma, 77 EBC, and 400 urine samples collected from nominally healthy adults subjects in North Carolina in 2008–2012. The <italic>in vivo</italic> results show that there is sufficient sensitivity for characterizing all 10 cytokines at levels of 0.05–0.10 ρg/ml with a dynamic range up to 100 ng/ml across all three of these biological media. The measured <italic>in vivo</italic> results also show that the duplicate analysis of blood, EBC and urine samples have average estimated fold ranges of 2.21, 3.49, and 2.50, respectively, which are similar to the mean estimated fold range (2.88) for the lowest concentration (0.610 ρg/ml) from a series of spiked control samples; the cytokine method can be used for all three biological media. Nine out of the 10 cytokines measured in EBC were highly correlated within one another with Spearman ρ coefficients ranging from 0.679 to 0.852, while the cytokines measured in blood had a mix of negative and positive correlations, ranging from −0.620 to 0.836. Almost all correlations between EBC and blood were positive. This work also represents the first successful within- and between-person evaluation of ultra trace-level inflammatory markers in blood, EBC, and urine.</p> </abstract> … (more)
- Is Part Of:
- Biomarkers. Volume 20:Number 1(2015)
- Journal:
- Biomarkers
- Issue:
- Volume 20:Number 1(2015)
- Issue Display:
- Volume 20, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2015-0020-0001-0000
- Page Start:
- 35
- Page End:
- 46
- Publication Date:
- 2015-02
- Subjects:
- Biochemical markers -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/bmk ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/alphalist.html ↗ - DOI:
- 10.3109/1354750X.2014.988646 ↗
- Languages:
- English
- ISSNs:
- 1354-750X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.704500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3674.xml