The Socket‐Shield Technique: First Histological, Clinical, and Volumetrical Observations after Separation of the Buccal Tooth Segment – A Pilot Study. (30th April 2013)
- Record Type:
- Journal Article
- Title:
- The Socket‐Shield Technique: First Histological, Clinical, and Volumetrical Observations after Separation of the Buccal Tooth Segment – A Pilot Study. (30th April 2013)
- Main Title:
- The Socket‐Shield Technique: First Histological, Clinical, and Volumetrical Observations after Separation of the Buccal Tooth Segment – A Pilot Study
- Authors:
- Bäumer, Daniel
Zuhr, Otto
Rebele, Stephan
Schneider, David
Schupbach, Peter
Hürzeler, Markus - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12076-sec-0001" sec-type="section"> <title>Background</title> <p>The "socket‐shield technique" has shown its potential in preserving buccal tissues. However, front teeth often have to be extracted due to vertical fractures in buccolingual direction. It has not yet been investigated if the socket‐shield technique can only be used with intact roots or also works with a modified shield design referring to vertical fracture lines.</p> </sec> <sec id="cid12076-sec-0002" sec-type="section"> <title>Purpose</title> <p>The aim of this study was to assess histologically, clinically, and volumetrically the effect of separating the remaining buccal root segment in two pieces before immediate implant placement.</p> </sec> <sec id="cid12076-sec-0003" sec-type="section"> <title>Material and Methods</title> <p>Three beagle dogs were selected in the study. The third and fourth premolars on both sides of the upper jaw were hemisected and the clinical crown of the distal root was removed. Then, the implant bed preparation was performed into the distal root so that a buccal segment of healthy tooth structure remained. This segment was then separated in a vertical direction into two pieces and implants placed lingual to it. After 4 months of healing, the specimens were processed for histological diagnosis. In a clinical case, the same technique was applied and impressions taken for volumetric evaluation by digital<abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12076-sec-0001" sec-type="section"> <title>Background</title> <p>The "socket‐shield technique" has shown its potential in preserving buccal tissues. However, front teeth often have to be extracted due to vertical fractures in buccolingual direction. It has not yet been investigated if the socket‐shield technique can only be used with intact roots or also works with a modified shield design referring to vertical fracture lines.</p> </sec> <sec id="cid12076-sec-0002" sec-type="section"> <title>Purpose</title> <p>The aim of this study was to assess histologically, clinically, and volumetrically the effect of separating the remaining buccal root segment in two pieces before immediate implant placement.</p> </sec> <sec id="cid12076-sec-0003" sec-type="section"> <title>Material and Methods</title> <p>Three beagle dogs were selected in the study. The third and fourth premolars on both sides of the upper jaw were hemisected and the clinical crown of the distal root was removed. Then, the implant bed preparation was performed into the distal root so that a buccal segment of healthy tooth structure remained. This segment was then separated in a vertical direction into two pieces and implants placed lingual to it. After 4 months of healing, the specimens were processed for histological diagnosis. In a clinical case, the same technique was applied and impressions taken for volumetric evaluation by digital superimposition.</p> </sec> <sec id="cid12076-sec-0004" sec-type="section"> <title>Results</title> <p>The tooth segments showed healthy periodontal ligament on the buccal side. New bone was visible between implant surface and shield as well as inside the vertical drill line. No osteoclastic remodeling of the coronal part of the buccal plate was observed. The clinical volumetric analysis showed a mean loss of 0.88 mm in labial direction with a maximum of 1.67 mm and a minimum of 0.15 mm.</p> </sec> <sec id="cid12076-sec-0005" sec-type="section"> <title>Conclusion</title> <p>The applied modification seems not to interfere with implant osseointegration and may still preserve the buccal plate. It may offer a feasible treatment option for vertically fractured teeth.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 17:Number 1(2015:Feb.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 17:Number 1(2015:Feb.)
- Issue Display:
- Volume 17, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2015-0017-0001-0000
- Page Start:
- 71
- Page End:
- 82
- Publication Date:
- 2013-04-30
- Subjects:
- Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/cid.12076 ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3746.xml