Pulsatile Venoarterial Perfusion Using a Novel Synchronized Cardiac Assist Device Augments Coronary Artery Blood Flow During Ventricular Fibrillation. Issue 1 (16th December 2014)
- Record Type:
- Journal Article
- Title:
- Pulsatile Venoarterial Perfusion Using a Novel Synchronized Cardiac Assist Device Augments Coronary Artery Blood Flow During Ventricular Fibrillation. Issue 1 (16th December 2014)
- Main Title:
- Pulsatile Venoarterial Perfusion Using a Novel Synchronized Cardiac Assist Device Augments Coronary Artery Blood Flow During Ventricular Fibrillation
- Authors:
- Cremers, Bodo
Link, Andreas
Werner, Christian
Gorhan, Holger
Simundic, Ivo
Matheis, Georg
Scheller, Bruno
Böhm, Michael
Laufs, Ulrich - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Patients with cardiogenic shock have a very high mortality. Here we report the first use of a percutaneous pulsatile cardiac assist device, based on a diagonal pump synchronized with the heart cycle by means of an electrocardiographic signal in adult pigs. Eight domestic pigs underwent mandatory ventilation. During sinus rhythm, there were no differences between pulsatile and nonpulsatile perfusion with regard to pulmonary artery pressure, pulmonary wedge pressure, central venous pressure, mean arterial pressure (MAP), mean pulse pressure, and mean coronary artery flow (CAF). After 2 min of complete cardiac arrest (ventricular fibrillation), circulatory support with the i‐cor in venoarterial nonpulsatile extracorporeal membrane oxygenation (ECMO) mode (3 L/min) restored systemic circulation, with an increase of MAP to 78.3 mm Hg and CAF to 5.27 mL/min. After changing from ECMO settings to pulsatile mode (3 L/min, 75 bpm, pulse amplitude range 3500 rpm), MAP did not change significantly (75.6 mm Hg); however, CAF increased to 8.45 mL/min. After changing back to nonpulsatile mode, MAP remained stable (83.6 mm Hg), but CAF decreased to 4.85 mL/min. Thereafter, pulsatile cardiac assist was established with a reduced blood flow of 2.5 L/min, and the pulse amplitude range was extended to 4500 rpm. Under these conditions, MAP remained stable (71.0 mm Hg), but CAF significantly increased to 15.2 mL/min<abstract abstract-type="main"> <title>Abstract</title> <p>Patients with cardiogenic shock have a very high mortality. Here we report the first use of a percutaneous pulsatile cardiac assist device, based on a diagonal pump synchronized with the heart cycle by means of an electrocardiographic signal in adult pigs. Eight domestic pigs underwent mandatory ventilation. During sinus rhythm, there were no differences between pulsatile and nonpulsatile perfusion with regard to pulmonary artery pressure, pulmonary wedge pressure, central venous pressure, mean arterial pressure (MAP), mean pulse pressure, and mean coronary artery flow (CAF). After 2 min of complete cardiac arrest (ventricular fibrillation), circulatory support with the i‐cor in venoarterial nonpulsatile extracorporeal membrane oxygenation (ECMO) mode (3 L/min) restored systemic circulation, with an increase of MAP to 78.3 mm Hg and CAF to 5.27 mL/min. After changing from ECMO settings to pulsatile mode (3 L/min, 75 bpm, pulse amplitude range 3500 rpm), MAP did not change significantly (75.6 mm Hg); however, CAF increased to 8.45 mL/min. After changing back to nonpulsatile mode, MAP remained stable (83.6 mm Hg), but CAF decreased to 4.85 mL/min. Thereafter, pulsatile cardiac assist was established with a reduced blood flow of 2.5 L/min, and the pulse amplitude range was extended to 4500 rpm. Under these conditions, MAP remained stable (71.0 mm Hg), but CAF significantly increased to 15.2 mL/min (<italic>P</italic> &lt; 0.05). Percutaneous cardiac support using a venoarterial cardiac assist device equipped with a novel diagonal pump is able to restore and increase systemic and coronary circulation during ventricular fibrillation. Electrocardiographically triggered synchronized cardiac assist provides an additional increase of coronary artery flow. These promising results are to be confirmed in humans.</p> </abstract> … (more)
- Is Part Of:
- Artificial organs. Volume 39:Issue 1(2015:Jan.)
- Journal:
- Artificial organs
- Issue:
- Volume 39:Issue 1(2015:Jan.)
- Issue Display:
- Volume 39, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2015-0039-0001-0000
- Page Start:
- 77
- Page End:
- 82
- Publication Date:
- 2014-12-16
- Subjects:
- Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.12413 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3308.xml