Multi‐sensing NDT for damage assessment of concrete masonry walls. Issue 3 (29th July 2014)
- Record Type:
- Journal Article
- Title:
- Multi‐sensing NDT for damage assessment of concrete masonry walls. Issue 3 (29th July 2014)
- Main Title:
- Multi‐sensing NDT for damage assessment of concrete masonry walls
- Authors:
- Khan, Fuad
Rajaram, Satish
Vanniamparambil, Prashanth A.
Bolhassani, Mohammad
Hamid, Ahmad
Kontsos, Antonios
Bartoli, Ivan - Abstract:
- <abstract abstract-type="main"> <title>Summary</title> <p>This paper presents a hybrid non‐destructive testing (NDT) approach based on (non‐contact) infrared thermography (IRT), (passive) acoustic emission (AE), and (active) ultrasonic (UT) techniques for effective damage assessment of partially grouted concrete masonry walls (PGMW). This hybrid monitoring approach could be implemented for the health monitoring of concrete masonry structures. The implementation of this system assists the cross validation of in‐situ recorded information for structural damage assessment. NDT was performed on PGMW subjected to cyclic horizontal loading. The obtained IRT, AE, and UT results successfully monitored the progressive damage process throughout the loading history. Copyright © 2014 John Wiley & Sons, Ltd.</p> </abstract>
- Is Part Of:
- Structural control and health monitoring. Volume 22:Issue 3(2015)
- Journal:
- Structural control and health monitoring
- Issue:
- Volume 22:Issue 3(2015)
- Issue Display:
- Volume 22, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2015-0022-0003-0000
- Page Start:
- 449
- Page End:
- 462
- Publication Date:
- 2014-07-29
- Subjects:
- Structural engineering -- Periodicals
Structural control (Engineering) -- Periodicals
Automatic data collection systems -- Periodicals
Detectors -- Periodicals
624.17 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/stc.1680 ↗
- Languages:
- English
- ISSNs:
- 1545-2255
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8476.924000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3908.xml