Effects of Different Extents of Pulley Release on Tendon Excursion Efficiency and Tendon Moment Arms. Issue 2 (8th October 2014)
- Record Type:
- Journal Article
- Title:
- Effects of Different Extents of Pulley Release on Tendon Excursion Efficiency and Tendon Moment Arms. Issue 2 (8th October 2014)
- Main Title:
- Effects of Different Extents of Pulley Release on Tendon Excursion Efficiency and Tendon Moment Arms
- Authors:
- Lu, Szu‐Ching
Yang, Tai‐Hua
Kuo, Li‐Chieh
Jou, I‐Ming
Sun, Yung‐Nien
Su, Fong‐Chin - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <sec id="jor22747-sec-0001" sec-type="section"> <p>To compare the excursion efficiency and moment arms of flexor digitorum superficialis (FDS) and profundus (FDP) among different conditions of pulley integrity related to trigger finger treatment, cadaveric fingers were first tested with an intact pulley system, and then the first (A1) and second (A2) annular pulleys were released gradually from the proximal to distal part. Linear position sensors and a motion capture system were used to measure the tendon excursion and joint rotation simultaneously. The tendon excursion efficiency was defined as the range of motion of the involved joints per unit of tendon excursion, and the tendon moment arm was determined by the slope of the linear fitting result of tendon excursion versus metacarpophalangeal (MCP) joint rotation. No significant differences were found between the release of the A1 pulley and the release extending to half the proximal part of the A2 pulley in the FDP excursion efficiency and the moment arms of FDS and FDP with respect to the MCP joint. These results imply that the release could extend to half the proximal A2 pulley, if necessary, without significantly decreasing the FDP excursion efficiency and increasing the moment arms of FDS and FDP with respect to the MCP joint. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:224–228, 2015.</p> </sec><abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <sec id="jor22747-sec-0001" sec-type="section"> <p>To compare the excursion efficiency and moment arms of flexor digitorum superficialis (FDS) and profundus (FDP) among different conditions of pulley integrity related to trigger finger treatment, cadaveric fingers were first tested with an intact pulley system, and then the first (A1) and second (A2) annular pulleys were released gradually from the proximal to distal part. Linear position sensors and a motion capture system were used to measure the tendon excursion and joint rotation simultaneously. The tendon excursion efficiency was defined as the range of motion of the involved joints per unit of tendon excursion, and the tendon moment arm was determined by the slope of the linear fitting result of tendon excursion versus metacarpophalangeal (MCP) joint rotation. No significant differences were found between the release of the A1 pulley and the release extending to half the proximal part of the A2 pulley in the FDP excursion efficiency and the moment arms of FDS and FDP with respect to the MCP joint. These results imply that the release could extend to half the proximal A2 pulley, if necessary, without significantly decreasing the FDP excursion efficiency and increasing the moment arms of FDS and FDP with respect to the MCP joint. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:224–228, 2015.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 33:Issue 2(2015:Feb.)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 33:Issue 2(2015:Feb.)
- Issue Display:
- Volume 33, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2015-0033-0002-0000
- Page Start:
- 224
- Page End:
- 228
- Publication Date:
- 2014-10-08
- Subjects:
- Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.22747 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3363.xml