Automatic iceball segmentation with adapted shape priors for MRI‐guided cryoablation. Issue 2 (12th December 2013)
- Record Type:
- Journal Article
- Title:
- Automatic iceball segmentation with adapted shape priors for MRI‐guided cryoablation. Issue 2 (12th December 2013)
- Main Title:
- Automatic iceball segmentation with adapted shape priors for MRI‐guided cryoablation
- Authors:
- Liu, Xinyang
Tuncali, Kemal
Wells, William M.
Zientara, Gary P. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24531-sec-0001" sec-type="section"> <title>Purpose</title> <p>To develop and evaluate an automatic segmentation method that extracts the 3D configuration of the ablation zone, the iceball, from images acquired during the freezing phase of MRI‐guided cryoablation.</p> </sec> <sec id="jmri24531-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Intraprocedural images at 63 timepoints from 13 kidney tumor cryoablation procedures were examined retrospectively. The images were obtained using a 3 Tesla wide‐bore MRI scanner and axial HASTE sequence. Initialized with semiautomatically localized cryoprobes, the iceball was segmented automatically at each timepoint using the graph cut (GC) technique with adapted shape priors.</p> </sec> <sec id="jmri24531-sec-0003" sec-type="section"> <title>Results</title> <p>The average Dice Similarity Coefficients (DSC), compared with manual segmentations, were 0.88, 0.92, 0.92, 0.93, and 0.93 at 3, 6, 9, 12, and 15 min timepoints, respectively, and the average DSC of the total 63 segmentations was 0.92 ± 0.03. The proposed method improved the accuracy significantly compared with the approach without shape prior adaptation (<italic>P</italic> = 0.026). The number of probes involved in the procedure had no apparent influence on the segmentation results using our technique. The average computation time was 20 s, which was compatible<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24531-sec-0001" sec-type="section"> <title>Purpose</title> <p>To develop and evaluate an automatic segmentation method that extracts the 3D configuration of the ablation zone, the iceball, from images acquired during the freezing phase of MRI‐guided cryoablation.</p> </sec> <sec id="jmri24531-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Intraprocedural images at 63 timepoints from 13 kidney tumor cryoablation procedures were examined retrospectively. The images were obtained using a 3 Tesla wide‐bore MRI scanner and axial HASTE sequence. Initialized with semiautomatically localized cryoprobes, the iceball was segmented automatically at each timepoint using the graph cut (GC) technique with adapted shape priors.</p> </sec> <sec id="jmri24531-sec-0003" sec-type="section"> <title>Results</title> <p>The average Dice Similarity Coefficients (DSC), compared with manual segmentations, were 0.88, 0.92, 0.92, 0.93, and 0.93 at 3, 6, 9, 12, and 15 min timepoints, respectively, and the average DSC of the total 63 segmentations was 0.92 ± 0.03. The proposed method improved the accuracy significantly compared with the approach without shape prior adaptation (<italic>P</italic> = 0.026). The number of probes involved in the procedure had no apparent influence on the segmentation results using our technique. The average computation time was 20 s, which was compatible with an intraprocedural setting.</p> </sec> <sec id="jmri24531-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Our automatic iceball segmentation method demonstrated high accuracy and robustness for practical use in monitoring the progress of MRI‐guided cryoablation. <bold>J. Magn. Reson. Imaging 2015;41:517–524.</bold>© <bold>2013 Wiley Periodicals, Inc</bold>.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 41:Issue 2(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 41:Issue 2(2015)
- Issue Display:
- Volume 41, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2015-0041-0002-0000
- Page Start:
- 517
- Page End:
- 524
- Publication Date:
- 2013-12-12
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24531 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3493.xml