Efficacy and safety of endoscopic interventions using the short double‐balloon endoscope in patients after incomplete colonoscopy. Issue 1 (16th October 2014)
- Record Type:
- Journal Article
- Title:
- Efficacy and safety of endoscopic interventions using the short double‐balloon endoscope in patients after incomplete colonoscopy. Issue 1 (16th October 2014)
- Main Title:
- Efficacy and safety of endoscopic interventions using the short double‐balloon endoscope in patients after incomplete colonoscopy
- Authors:
- Hotta, Kinichi
Katsuki, Shinichi
Ohata, Ken
Abe, Takashi
Endo, Masaki
Shimatani, Masaaki
Nagaya, Tadanobu
Kusaka, Toshihiro
Matsuda, Tomoki
Uraoka, Toshio
Yamaguchi, Yuichiro
Murakami, Yoshitaka
Saito, Yutaka - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="den12318-sec-0001" sec-type="section"> <title>Background and Aim</title> <p>We have previously reported excellent cecal intubation rates using a short double‐balloon endoscope in patients with a history of incomplete colonoscopy. However, data on the endoscopic treatment of colorectal tumors using a double‐balloon endoscope are limited. The aim of the present study was to evaluate the efficacy and safety of endoscopic intervention of colorectal tumors using a short double‐balloon endoscope.</p> </sec> <sec id="den12318-sec-0002" sec-type="section"> <title>Methods</title> <p>We analyzed data from a multicenter, prospective study on 110 patients (62 men, median age 66.5 years) who underwent total colonoscopy after incomplete colonoscopy to assess the characteristics of colorectal tumors, endoscopic interventions, and complications.</p> </sec> <sec id="den12318-sec-0003" sec-type="section"> <title>Results</title> <p>In all, 113 colorectal tumors were detected in 55 patients; 109 of the tumors were adenomas (24 advanced adenomas) and two each were intramucosal and advanced cancers. Locations of the lesions were eight in the cecum, 30 in the ascending colon, 18 in the transverse colon, 12 in the descending colon, 34 in the sigmoid colon, five in the rectosigmoid and six in the rectum. Average tumor diameter was 6.8 ± 6.3 mm. Fifty‐nine polypectomies, 22 endoscopic mucosal resections,<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="den12318-sec-0001" sec-type="section"> <title>Background and Aim</title> <p>We have previously reported excellent cecal intubation rates using a short double‐balloon endoscope in patients with a history of incomplete colonoscopy. However, data on the endoscopic treatment of colorectal tumors using a double‐balloon endoscope are limited. The aim of the present study was to evaluate the efficacy and safety of endoscopic intervention of colorectal tumors using a short double‐balloon endoscope.</p> </sec> <sec id="den12318-sec-0002" sec-type="section"> <title>Methods</title> <p>We analyzed data from a multicenter, prospective study on 110 patients (62 men, median age 66.5 years) who underwent total colonoscopy after incomplete colonoscopy to assess the characteristics of colorectal tumors, endoscopic interventions, and complications.</p> </sec> <sec id="den12318-sec-0003" sec-type="section"> <title>Results</title> <p>In all, 113 colorectal tumors were detected in 55 patients; 109 of the tumors were adenomas (24 advanced adenomas) and two each were intramucosal and advanced cancers. Locations of the lesions were eight in the cecum, 30 in the ascending colon, 18 in the transverse colon, 12 in the descending colon, 34 in the sigmoid colon, five in the rectosigmoid and six in the rectum. Average tumor diameter was 6.8 ± 6.3 mm. Fifty‐nine polypectomies, 22 endoscopic mucosal resections, four hot biopsies, and six cold biopsies were done. All endoscopic interventions were successfully completed and no complications were noted. Two advanced cancers were located in the ascending colon and only a double‐balloon endoscope could reach them to take a biopsy sample.</p> </sec> <sec id="den12318-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Double‐balloon endoscopy is effective and safe for endoscopic intervention of colorectal tumors, irrespective of the location, in patients after incomplete colonoscopy.</p> </sec> </abstract> … (more)
- Is Part Of:
- Digestive endoscopy. Volume 27:Issue 1(2015)
- Journal:
- Digestive endoscopy
- Issue:
- Volume 27:Issue 1(2015)
- Issue Display:
- Volume 27, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2015-0027-0001-0000
- Page Start:
- 95
- Page End:
- 98
- Publication Date:
- 2014-10-16
- Subjects:
- Digestive organs -- Diseases -- Periodicals
Digestive organs -- Diseases -- Diagnosis -- Periodicals
Endoscopy -- Periodicals
Digestive System Diseases -- diagnosis -- Periodicals
Digestive System Diseases -- therapy -- Periodicals
Endoscopy -- Periodicals
616.3 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/den.12318 ↗
- Languages:
- English
- ISSNs:
- 0915-5635
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3588.346200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3607.xml