The importance of EN ISO 15189 accreditation of allergen‐specific IgE determination for reliable in vitro allergy diagnosis. Issue 2 (February 2015)
- Record Type:
- Journal Article
- Title:
- The importance of EN ISO 15189 accreditation of allergen‐specific IgE determination for reliable in vitro allergy diagnosis. Issue 2 (February 2015)
- Main Title:
- The importance of EN ISO 15189 accreditation of allergen‐specific IgE determination for reliable in vitro allergy diagnosis
- Authors:
- Lambert, C.
Sarrat, A.
Bienvenu, F.
Brabant, S.
Nicaise‐Roland, P.
Alyanakian, M.‐A.
Apoil, P.‐A.
Capron, C.
Couderc, R.
Evrard, B.
Jaby, D.
Hémont, C.
Lainé, C.
Lelong, M.
Mariotte, D.
Martinet, J.
Rénier, G.
Sainte‐Laudy, J.
Tabary, T.
Treiner, E.
Uring‐Lambert, B.
Vigneron, C.
Vivinus, M.
Witthuhn, F.
Vitte, J.
on behalf of the AllergoBioNet sIgE accreditation interest group - Abstract:
- <abstract abstract-type="main" id="all12546-abs-0001"> <title>Abstract</title> <sec id="all12546-sec-0001" sec-type="section"> <title>Background</title> <p>Allergen‐specific serum immunoglobulin E detection and quantification have become an important step in allergy diagnosis and follow‐up. In line with the current trend of laboratory test accreditation to international standards, we set out to design and assess an accreditation procedure for allergen‐specific serum IgE.</p> </sec> <sec id="all12546-sec-0002" sec-type="section"> <title>Methods</title> <p>Method validation according to the accreditation procedure under the EN ISO 15189 standard was carried out for allergen‐specific immunoglobulin E determination using the fluoroimmunoenzymatic method ImmunoCAP<sup>®</sup> (ThermoFisher). Data were produced by 25 hospital laboratories in France. A total of 29 allergen specificities including mixes, extracts, and molecular allergens were assayed. Allergen‐specific serum immunoglobulin E concentrations ranged from 0.1 to 100 kU<sub>A</sub>/l.</p> </sec> <sec id="all12546-sec-0003" sec-type="section"> <title>Results</title> <p>Repeatability, reproducibility, and accuracy results fulfilled method validation criteria for automated laboratory tests and proved similar irrespective of the allergen specificity, allergen‐specific serum immunoglobulin E concentration, or individual laboratory.</p> </sec> <sec id="all12546-sec-0004" sec-type="section"> <title>Conclusion</title><abstract abstract-type="main" id="all12546-abs-0001"> <title>Abstract</title> <sec id="all12546-sec-0001" sec-type="section"> <title>Background</title> <p>Allergen‐specific serum immunoglobulin E detection and quantification have become an important step in allergy diagnosis and follow‐up. In line with the current trend of laboratory test accreditation to international standards, we set out to design and assess an accreditation procedure for allergen‐specific serum IgE.</p> </sec> <sec id="all12546-sec-0002" sec-type="section"> <title>Methods</title> <p>Method validation according to the accreditation procedure under the EN ISO 15189 standard was carried out for allergen‐specific immunoglobulin E determination using the fluoroimmunoenzymatic method ImmunoCAP<sup>®</sup> (ThermoFisher). Data were produced by 25 hospital laboratories in France. A total of 29 allergen specificities including mixes, extracts, and molecular allergens were assayed. Allergen‐specific serum immunoglobulin E concentrations ranged from 0.1 to 100 kU<sub>A</sub>/l.</p> </sec> <sec id="all12546-sec-0003" sec-type="section"> <title>Results</title> <p>Repeatability, reproducibility, and accuracy results fulfilled method validation criteria for automated laboratory tests and proved similar irrespective of the allergen specificity, allergen‐specific serum immunoglobulin E concentration, or individual laboratory.</p> </sec> <sec id="all12546-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Allergen‐specific serum immunoglobulin E determination with the fluoroimmunoenzymatic method ImmunoCAP<sup>®</sup> is a highly repeatable, reproducible, and accurate method which may be considered as a single analyte assay in view of the EN ISO 15189 accreditation procedure.</p> </sec> </abstract> … (more)
- Is Part Of:
- Allergy. Volume 70:Issue 2(2015:Feb.)
- Journal:
- Allergy
- Issue:
- Volume 70:Issue 2(2015:Feb.)
- Issue Display:
- Volume 70, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 70
- Issue:
- 2
- Issue Sort Value:
- 2015-0070-0002-0000
- Page Start:
- 180
- Page End:
- 186
- Publication Date:
- 2015-02
- Subjects:
- Allergy -- Periodicals
616.97 - Journal URLs:
- http://estar.bl.uk/cgi-bin/sciserv.pl?collection=journals&journal=01054538 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1398-9995 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/all.12546 ↗
- Languages:
- English
- ISSNs:
- 0105-4538
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0790.945000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3496.xml