High resolution diffusion tensor imaging of human nerves in forearm. Issue 6 (14th November 2013)
- Record Type:
- Journal Article
- Title:
- High resolution diffusion tensor imaging of human nerves in forearm. Issue 6 (14th November 2013)
- Main Title:
- High resolution diffusion tensor imaging of human nerves in forearm
- Authors:
- Zhou, Yuxiang
Narayana, Ponnada A.
Kumaravel, Manickam
Athar, Parveen
Patel, Vipulkumar S.
Sheikh, Kazim A. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24300-sec-0001" sec-type="section"> <title>Purpose</title> <p>To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm.</p> </sec> <sec id="jmri24300-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>This HIPAA‐compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T<sub>1</sub>‐and T<sub>2</sub>‐weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0 × 1.0 × 3.0 mm<sup>3</sup>) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ<sub>//</sub>) and radial diffusivity (λ<sub>⊥</sub>) were generated.</p> </sec> <sec id="jmri24300-sec-0003" sec-type="section"> <title>Results</title> <p>For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI‐derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI‐derived measures, FA, MD, λ<sub>//</sub> and λ<sub>⊥</sub>, were observed among the three nerves.<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24300-sec-0001" sec-type="section"> <title>Purpose</title> <p>To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm.</p> </sec> <sec id="jmri24300-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>This HIPAA‐compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T<sub>1</sub>‐and T<sub>2</sub>‐weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0 × 1.0 × 3.0 mm<sup>3</sup>) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ<sub>//</sub>) and radial diffusivity (λ<sub>⊥</sub>) were generated.</p> </sec> <sec id="jmri24300-sec-0003" sec-type="section"> <title>Results</title> <p>For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI‐derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI‐derived measures, FA, MD, λ<sub>//</sub> and λ<sub>⊥</sub>, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T<sub>2</sub>‐weighted images was observed.</p> </sec> <sec id="jmri24300-sec-0004" sec-type="section"> <title>Conclusion</title> <p>High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI. These normative data could potentially help in identifying pathology in diseased nerves. <bold>J. Magn. Reson. Imaging 2014;39:1374–1383</bold>. © <bold>2013 Wiley Periodicals, Inc</bold>.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 39:Issue 6(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 39:Issue 6(2014)
- Issue Display:
- Volume 39, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 6
- Issue Sort Value:
- 2014-0039-0006-0000
- Page Start:
- 1374
- Page End:
- 1383
- Publication Date:
- 2013-11-14
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24300 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4192.xml