Incremental Value of Three‐Dimensional Transesophageal Echocardiography over Two‐Dimensional Transesophageal Echocardiography in the Assessment of Lambl's Excrescences and Nodules of Arantius on the Aortic Valve. Issue 8 (27th July 2013)
- Record Type:
- Journal Article
- Title:
- Incremental Value of Three‐Dimensional Transesophageal Echocardiography over Two‐Dimensional Transesophageal Echocardiography in the Assessment of Lambl's Excrescences and Nodules of Arantius on the Aortic Valve. Issue 8 (27th July 2013)
- Main Title:
- Incremental Value of Three‐Dimensional Transesophageal Echocardiography over Two‐Dimensional Transesophageal Echocardiography in the Assessment of Lambl's Excrescences and Nodules of Arantius on the Aortic Valve
- Authors:
- Dumaswala, Bhavin
Dumaswala, Komal
Hsiung, Ming Chon
Quiroz, Luis David Meggo
Sungur, Aylin
Escanuela, Maximilliano German Amado
Mehta, Kruti
Oz, Tugba Kemaloglu
Bhagatwala, Kunal
Karia, Nidhi M.
Nanda, Navin C. - Abstract:
- <abstract abstract-type="main" id="echo12310-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <p>In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two‐dimensional transesophageal echocardiography (2DTEE) and also had live/real time three‐dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x‐, y‐, and z‐axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x‐, y‐, and z‐ axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve.</p> </abstract>
- Is Part Of:
- Echocardiography. Volume 30:Issue 8(2013)
- Journal:
- Echocardiography
- Issue:
- Volume 30:Issue 8(2013)
- Issue Display:
- Volume 30, Issue 8 (2013)
- Year:
- 2013
- Volume:
- 30
- Issue:
- 8
- Issue Sort Value:
- 2013-0030-0008-0000
- Page Start:
- 967
- Page End:
- 975
- Publication Date:
- 2013-07-27
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12310 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4359.xml