Left Atrial Deformation Parameters Predict Left Atrial Appendage Function and Thrombus in Patients in Sinus Rhythm with Suspected Cardioembolic Stroke: A Speckle Tracking and Transesophageal Echocardiography Study. Issue 5 (11th January 2013)
- Record Type:
- Journal Article
- Title:
- Left Atrial Deformation Parameters Predict Left Atrial Appendage Function and Thrombus in Patients in Sinus Rhythm with Suspected Cardioembolic Stroke: A Speckle Tracking and Transesophageal Echocardiography Study. Issue 5 (11th January 2013)
- Main Title:
- Left Atrial Deformation Parameters Predict Left Atrial Appendage Function and Thrombus in Patients in Sinus Rhythm with Suspected Cardioembolic Stroke: A Speckle Tracking and Transesophageal Echocardiography Study
- Authors:
- Karabay, Can Yücel
Zehir, Regayip
Güler, Ahmet
Oduncu, Vecih
Kalayci, Arzu
Aung, Soe Moe
Karagoz, Ali
Tanboga, Ibrahim Halil
Candan, Ozkan
Gecmen, Cetin
Erkol, Ayhan
Esen, Ali Metin
Kirma, Cevat - Abstract:
- <abstract abstract-type="main" id="echo12089-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The aim of this study was to evaluate left atrial deformations using speckle tracking echocardiography for predicting left atrial appendage (LAA) thrombus in patients with suspected cardioembolic stroke who were in normal sinus rhythm. A total of 153 ischemic stroke patients (89 males, 64 females) in sinus rhythm who were suspected of having cardioembolism were included in the study. The patients underwent conventional two‐dimensional (2D) echocardiogram and 2D speckle tracking echocardiogram of the left atrium. Left atrial peak strain (LA‐4C‐RES) and left atrial precontraction strain (LA‐4C‐PUMP) were measured. Patients were divided into 2 groups according to the presence of thrombus in the LAA in transesophageal echocardiography. Both LA‐4C‐RES and LA‐4C‐PUMP values were found to be significantly lower in patients with LAA thrombus (11.8 ± 1.4% vs. 33 ± 12%, P &lt; 0.001 and 5.8 ± 1.3% vs. 14.2 ± 5.3%, P &lt; 0.001, respectively). A good inverse correlation was present between LA‐4C‐RES values and LAA morphologic parameters (with LAA area: r = −0.70, P &lt; 0.001, with LAA length: r = −0.60, P &lt; 0.001), and a good positive correlation was present with LAA emptying velocity with pulse Doppler (r = 0.74, P &lt; 0.001). The area under the receiver‐operating characteristic curve of the LA‐4C‐RES was 0.94 (0.90–0.98, P &lt; 0.001), for the LA‐4C‐PUMP, the area was<abstract abstract-type="main" id="echo12089-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The aim of this study was to evaluate left atrial deformations using speckle tracking echocardiography for predicting left atrial appendage (LAA) thrombus in patients with suspected cardioembolic stroke who were in normal sinus rhythm. A total of 153 ischemic stroke patients (89 males, 64 females) in sinus rhythm who were suspected of having cardioembolism were included in the study. The patients underwent conventional two‐dimensional (2D) echocardiogram and 2D speckle tracking echocardiogram of the left atrium. Left atrial peak strain (LA‐4C‐RES) and left atrial precontraction strain (LA‐4C‐PUMP) were measured. Patients were divided into 2 groups according to the presence of thrombus in the LAA in transesophageal echocardiography. Both LA‐4C‐RES and LA‐4C‐PUMP values were found to be significantly lower in patients with LAA thrombus (11.8 ± 1.4% vs. 33 ± 12%, P &lt; 0.001 and 5.8 ± 1.3% vs. 14.2 ± 5.3%, P &lt; 0.001, respectively). A good inverse correlation was present between LA‐4C‐RES values and LAA morphologic parameters (with LAA area: r = −0.70, P &lt; 0.001, with LAA length: r = −0.60, P &lt; 0.001), and a good positive correlation was present with LAA emptying velocity with pulse Doppler (r = 0.74, P &lt; 0.001). The area under the receiver‐operating characteristic curve of the LA‐4C‐RES was 0.94 (0.90–0.98, P &lt; 0.001), for the LA‐4C‐PUMP, the area was 0.92 (0.87–0.96, P &lt; 0.001) to predict LAA thrombus. Left atrial deformation parameters measured by 2D speckle tracking method was found to predict impaired LAA functions and the presence of LAA thrombus in ischemic stroke patients with suspected cardioembolism, but who are in sinus rhythm.</p> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 30:Issue 5(2013)
- Journal:
- Echocardiography
- Issue:
- Volume 30:Issue 5(2013)
- Issue Display:
- Volume 30, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2013-0030-0005-0000
- Page Start:
- 572
- Page End:
- 581
- Publication Date:
- 2013-01-11
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12089 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2985.xml