Efficacy of Pulmonary Vein Isolation on Left Atrial Function in Paroxysmal and Persistent Atrial Fibrillation and the Dependency on Its Baseline Function. Issue 7 (6th March 2013)
- Record Type:
- Journal Article
- Title:
- Efficacy of Pulmonary Vein Isolation on Left Atrial Function in Paroxysmal and Persistent Atrial Fibrillation and the Dependency on Its Baseline Function. Issue 7 (6th March 2013)
- Main Title:
- Efficacy of Pulmonary Vein Isolation on Left Atrial Function in Paroxysmal and Persistent Atrial Fibrillation and the Dependency on Its Baseline Function
- Authors:
- Yoshida, Naoyasu
Okamoto, Mitsunori
Hirao, Hidekazu
Suenari, Kazuyoshi
Nanba, Kiyomi
Kinoshita, Hiroki
Matsumura, Masaya
Uchida, Mio
Kinoshita, Mirai
Watari, Yuichiro
Fukuda, Yukihiro
Ueda, Hironori - Abstract:
- <abstract abstract-type="main" id="echo12143-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12143-sec-0001" sec-type="section"> <title>Background</title> <p>The effects of pulmonary vein (PV) isolation in atrial fibrillation (AF) on left atrial (LA) function or PV flow have not been well documented.</p> </sec> <sec id="echo12143-sec-0002" sec-type="section"> <title>Methods</title> <p>We examined the LA function and PV flow before and 3–6 months after PV isolation in 67 AF patients (34 paroxysmal [PAF] and 33 persistent [CAF]) using transesophageal echocardiography.</p> </sec> <sec id="echo12143-sec-0003" sec-type="section"> <title>Results</title> <p>AF recurred in 6/34 patients with PAF and in 6/33 patients with CAF 6 months after PV isolation. A larger LA dimension, a lower systolic PV flow velocity, and a lower ratio of systolic to diastolic PV flow velocity were related to a higher incidence of AF recurrence. The increment of left atrial appendage (LAA) flow velocity (55% vs. 22%) and systolic PV flow velocity (57% vs. 20%) after PV isolation tended to be greater in CAF than in PAF. The changes in LAA flow velocity had reverse correlations with the baseline values before PV isolation (PAF: r = −0.73, CAF: r = −0.58). The changes in mitral flow velocity during atrial contraction in PAF had reverse correlations with the baseline values before PV isolation (r = −0.84). The changes in systolic and diastolic PV flow velocity of PAF had reverse<abstract abstract-type="main" id="echo12143-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12143-sec-0001" sec-type="section"> <title>Background</title> <p>The effects of pulmonary vein (PV) isolation in atrial fibrillation (AF) on left atrial (LA) function or PV flow have not been well documented.</p> </sec> <sec id="echo12143-sec-0002" sec-type="section"> <title>Methods</title> <p>We examined the LA function and PV flow before and 3–6 months after PV isolation in 67 AF patients (34 paroxysmal [PAF] and 33 persistent [CAF]) using transesophageal echocardiography.</p> </sec> <sec id="echo12143-sec-0003" sec-type="section"> <title>Results</title> <p>AF recurred in 6/34 patients with PAF and in 6/33 patients with CAF 6 months after PV isolation. A larger LA dimension, a lower systolic PV flow velocity, and a lower ratio of systolic to diastolic PV flow velocity were related to a higher incidence of AF recurrence. The increment of left atrial appendage (LAA) flow velocity (55% vs. 22%) and systolic PV flow velocity (57% vs. 20%) after PV isolation tended to be greater in CAF than in PAF. The changes in LAA flow velocity had reverse correlations with the baseline values before PV isolation (PAF: r = −0.73, CAF: r = −0.58). The changes in mitral flow velocity during atrial contraction in PAF had reverse correlations with the baseline values before PV isolation (r = −0.84). The changes in systolic and diastolic PV flow velocity of PAF had reverse correlations with the baseline values before PV isolation (r = −0.56, r = −0.66).</p> </sec> <sec id="echo12143-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The baseline LA function may affect AF recurrence as well as the improvement of LA function, and the benefit of successful PV isolation might be greater in CAF than in PAF.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 30:Issue 7(2013)
- Journal:
- Echocardiography
- Issue:
- Volume 30:Issue 7(2013)
- Issue Display:
- Volume 30, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 30
- Issue:
- 7
- Issue Sort Value:
- 2013-0030-0007-0000
- Page Start:
- 744
- Page End:
- 750
- Publication Date:
- 2013-03-06
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12143 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3882.xml