Coronary Artery Wall Thickness of the Left Anterior Descending Artery Using High Resolution Transthoracic Echocardiography – Normal Range of Values. Issue 7 (25th January 2013)
- Record Type:
- Journal Article
- Title:
- Coronary Artery Wall Thickness of the Left Anterior Descending Artery Using High Resolution Transthoracic Echocardiography – Normal Range of Values. Issue 7 (25th January 2013)
- Main Title:
- Coronary Artery Wall Thickness of the Left Anterior Descending Artery Using High Resolution Transthoracic Echocardiography – Normal Range of Values
- Authors:
- Perry, Rebecca
Joseph, Majo X.
Chew, Derek P.
Aylward, Philip E.
De Pasquale, Carmine G. - Abstract:
- <abstract abstract-type="main" id="echo12136-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Recently it has been demonstrated that high resolution transthoracic echocardiography (HRTTE) is able to detect differences in the wall thickness of the left anterior descending coronary artery (LAD) between patients with coronary artery disease (CAD) and normal volunteers. We sought to validate this technique, develop a normal range of values and demonstrate the test–retest variability of each measurement. Two hundred forty‐two volunteer participants had a HRTTE study to measure their LAD wall thickness, luminal, and external diameters. Thirty of these subjects had these measurements taken on 3 separate occasions by 2 different echosonographers. All subjects were free of clinical CAD, hypertension, hyperlipidemia, and diabetes mellitus. The average anterior wall thickness was 1.1 ± 0.2 mm; posterior wall thickness was 1.1 ± 0.2 mm, luminal diameter 2.2 ± 0.6 mm, and external elastic membrane (EEM) diameter 4.5 ± 0.9 mm. The bias of the measurements within the same operator for LAD wall thickness, luminal diameter, and EEM was 0.042, −0.06, and −0.077 mm, respectively. The bias of the measurements between 2 different operators for LAD wall thickness, luminal diameter, and EEM was 0.082, −0.077, and −0.027 mm, respectively. In conclusion, HRTTE measurement of the LAD vessel is reproducible within and between operators in normal volunteers. This technique therefore<abstract abstract-type="main" id="echo12136-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Recently it has been demonstrated that high resolution transthoracic echocardiography (HRTTE) is able to detect differences in the wall thickness of the left anterior descending coronary artery (LAD) between patients with coronary artery disease (CAD) and normal volunteers. We sought to validate this technique, develop a normal range of values and demonstrate the test–retest variability of each measurement. Two hundred forty‐two volunteer participants had a HRTTE study to measure their LAD wall thickness, luminal, and external diameters. Thirty of these subjects had these measurements taken on 3 separate occasions by 2 different echosonographers. All subjects were free of clinical CAD, hypertension, hyperlipidemia, and diabetes mellitus. The average anterior wall thickness was 1.1 ± 0.2 mm; posterior wall thickness was 1.1 ± 0.2 mm, luminal diameter 2.2 ± 0.6 mm, and external elastic membrane (EEM) diameter 4.5 ± 0.9 mm. The bias of the measurements within the same operator for LAD wall thickness, luminal diameter, and EEM was 0.042, −0.06, and −0.077 mm, respectively. The bias of the measurements between 2 different operators for LAD wall thickness, luminal diameter, and EEM was 0.082, −0.077, and −0.027 mm, respectively. In conclusion, HRTTE measurement of the LAD vessel is reproducible within and between operators in normal volunteers. This technique therefore warrants further study as a potential screening modality for subclinical coronary atherosclerosis.</p> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 30:Issue 7(2013)
- Journal:
- Echocardiography
- Issue:
- Volume 30:Issue 7(2013)
- Issue Display:
- Volume 30, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 30
- Issue:
- 7
- Issue Sort Value:
- 2013-0030-0007-0000
- Page Start:
- 759
- Page End:
- 764
- Publication Date:
- 2013-01-25
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12136 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3882.xml