Performance of an External Transtelephonic Loop Recorder for Automated Detection of Paroxysmal Atrial Fibrillation. Issue 6 (9th September 2013)
- Record Type:
- Journal Article
- Title:
- Performance of an External Transtelephonic Loop Recorder for Automated Detection of Paroxysmal Atrial Fibrillation. Issue 6 (9th September 2013)
- Main Title:
- Performance of an External Transtelephonic Loop Recorder for Automated Detection of Paroxysmal Atrial Fibrillation
- Authors:
- Velthuis, Bob Oude
Bos, Jorieke
Kraaier, Karin
Stevenhagen, Jeroen
van, Jurren M.
van der, Job
Scholten, Marcoen F. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="anec12075-sec-0010" sec-type="section"> <title>Background</title> <p>Although atrial fibrillation (AF) is the most commonly encountered arrhythmia, some of the properties make its detection challenging. In daily practice, underdiagnosis can lead to less effective treatment in prevention of stroke. Based on data from studies on treatment of AF, more intensive follow‐up strategies, including 7‐day Holter recording, 30‐day event recording, and even implantable cardiac monitoring devices, are suggested. The study purpose is to evaluate the performance of a continuous single‐channel loop recorder with automatic AF detection and transtelephonic electrocardiogram (ECG) transmission capabilities.</p> </sec> <sec id="anec12075-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>A consecutive cohort of 153 patients admitted to the stroke unit with a presumptive diagnosis of ischemic cerebrovascular accident was screened for AF. Twenty‐four‐hour rhythm observation was performed using a single‐channel external loop recorder (ELR) configured for automated AF detection. A total of 45 patients with a known history of AF, AF on the admission ECG, or incomplete registrations were excluded. Extensive additional frequency‐based settings were used to establish a reference registration. In total, 2923 recordings were transmitted. We evaluated all events, of which 1190 were designated by<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="anec12075-sec-0010" sec-type="section"> <title>Background</title> <p>Although atrial fibrillation (AF) is the most commonly encountered arrhythmia, some of the properties make its detection challenging. In daily practice, underdiagnosis can lead to less effective treatment in prevention of stroke. Based on data from studies on treatment of AF, more intensive follow‐up strategies, including 7‐day Holter recording, 30‐day event recording, and even implantable cardiac monitoring devices, are suggested. The study purpose is to evaluate the performance of a continuous single‐channel loop recorder with automatic AF detection and transtelephonic electrocardiogram (ECG) transmission capabilities.</p> </sec> <sec id="anec12075-sec-0020" sec-type="section"> <title>Methods and Results</title> <p>A consecutive cohort of 153 patients admitted to the stroke unit with a presumptive diagnosis of ischemic cerebrovascular accident was screened for AF. Twenty‐four‐hour rhythm observation was performed using a single‐channel external loop recorder (ELR) configured for automated AF detection. A total of 45 patients with a known history of AF, AF on the admission ECG, or incomplete registrations were excluded. Extensive additional frequency‐based settings were used to establish a reference registration. In total, 2923 recordings were transmitted. We evaluated all events, of which 1190 were designated by the device as AF. The sensitivity, specificity, PPV, and NPV for identifying AF using the ELR were, respectively, 93%, 51%, 5%, and 99%.</p> </sec> <sec id="anec12075-sec-0030" sec-type="section"> <title>Conclusions</title> <p>In this ELR validation study, the dedicated AF detection algorithm showed to be highly sensitive but not specific for AF. Applicability of an ELR might be limited for efficacious detection of AF, as manual verification is mandatory for a vast amount of recordings.</p> </sec> </abstract> … (more)
- Is Part Of:
- Annals of noninvasive electrocardiology. Volume 18:Issue 6(2013:Nov.)
- Journal:
- Annals of noninvasive electrocardiology
- Issue:
- Volume 18:Issue 6(2013:Nov.)
- Issue Display:
- Volume 18, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 18
- Issue:
- 6
- Issue Sort Value:
- 2013-0018-0006-0000
- Page Start:
- 564
- Page End:
- 570
- Publication Date:
- 2013-09-09
- Subjects:
- Electrocardiography -- Periodicals
Arrhythmia -- Periodicals
616.1207547 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1542-474X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/anec.12075 ↗
- Languages:
- English
- ISSNs:
- 1082-720X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.144000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: