Efficacy of Carbon Dioxide Insufflation for Cerebral and Cardiac Protection During Open Heart Surgery: A Systematic Review and Meta‐Analysis. Issue 5 (19th March 2013)
- Record Type:
- Journal Article
- Title:
- Efficacy of Carbon Dioxide Insufflation for Cerebral and Cardiac Protection During Open Heart Surgery: A Systematic Review and Meta‐Analysis. Issue 5 (19th March 2013)
- Main Title:
- Efficacy of Carbon Dioxide Insufflation for Cerebral and Cardiac Protection During Open Heart Surgery: A Systematic Review and Meta‐Analysis
- Authors:
- Sun, Yanhua
Ji, Bingyang
Zhu, Xian
Zheng, Zhe - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>In spite of widespread application around the world, there has been controversy on the cerebral and cardiac protection efficacy of carbon dioxide insufflation (CDI) during open heart surgery. To make a comprehensive evaluation, we screened all relevant published randomized controlled trials to perform the first systematic review and meta‐analysis for CDI during open heart surgery. We searched PubMed, EMBASE, the Cochrane Controlled Clinical Trial register, WANFAN, CQVIP, and CNKI database for published articles. Randomized controlled trials were included when the research provided data of neurological complications postoperatively, creatinine kinase, MB isoenzyme (CK‐MB) on the first postoperative day, or all‐cause mortality. We chose a fixed‐effects model when the trials showed low heterogeneity, otherwise a random effects model was used. The quality of studies was assessed by modified Jadad scale. Four studies were included in this meta‐analysis. The overall pooled relative risk (RR) for neurological complications was 1.59, 95% confidence interval (CI) = [0.57, 4.46], and the <italic>z</italic>‐score for overall effect was 0.89 (<italic>P</italic> = 0.37). The standardized mean difference of the CK‐MB between groups was 1.15, 95% CI = [−1.27, 3.56], and the <italic>z</italic>‐score for overall effect was 0.93 (<italic>P</italic> = 0.35). The overall pooled RR for all‐cause mortality was 0.5, 95% CI = [0.16, 1.64],<abstract abstract-type="main"> <title>Abstract</title> <p>In spite of widespread application around the world, there has been controversy on the cerebral and cardiac protection efficacy of carbon dioxide insufflation (CDI) during open heart surgery. To make a comprehensive evaluation, we screened all relevant published randomized controlled trials to perform the first systematic review and meta‐analysis for CDI during open heart surgery. We searched PubMed, EMBASE, the Cochrane Controlled Clinical Trial register, WANFAN, CQVIP, and CNKI database for published articles. Randomized controlled trials were included when the research provided data of neurological complications postoperatively, creatinine kinase, MB isoenzyme (CK‐MB) on the first postoperative day, or all‐cause mortality. We chose a fixed‐effects model when the trials showed low heterogeneity, otherwise a random effects model was used. The quality of studies was assessed by modified Jadad scale. Four studies were included in this meta‐analysis. The overall pooled relative risk (RR) for neurological complications was 1.59, 95% confidence interval (CI) = [0.57, 4.46], and the <italic>z</italic>‐score for overall effect was 0.89 (<italic>P</italic> = 0.37). The standardized mean difference of the CK‐MB between groups was 1.15, 95% CI = [−1.27, 3.56], and the <italic>z</italic>‐score for overall effect was 0.93 (<italic>P</italic> = 0.35). The overall pooled RR for all‐cause mortality was 0.5, 95% CI = [0.16, 1.64], and the <italic>z</italic>‐score for overall effect was 1.14 (<italic>P</italic> = 0.25). There was no significant difference between groups. Because of the insufficiency of powerful evidences, the cerebral and cardiac protection efficacy of CDI during open heart surgery needs to be further verified by more high‐quality trials.</p> </abstract> … (more)
- Is Part Of:
- Artificial organs. Volume 37:Issue 5(2013:May)
- Journal:
- Artificial organs
- Issue:
- Volume 37:Issue 5(2013:May)
- Issue Display:
- Volume 37, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 5
- Issue Sort Value:
- 2013-0037-0005-0000
- Page Start:
- 439
- Page End:
- 446
- Publication Date:
- 2013-03-19
- Subjects:
- Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.12042 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3856.xml