Adsorption and recovery issues of recombinant monoclonal antibodies in reversed‐phase liquid chromatography†. Issue 1 (9th December 2014)
- Record Type:
- Journal Article
- Title:
- Adsorption and recovery issues of recombinant monoclonal antibodies in reversed‐phase liquid chromatography†. Issue 1 (9th December 2014)
- Main Title:
- Adsorption and recovery issues of recombinant monoclonal antibodies in reversed‐phase liquid chromatography†
- Authors:
- Fekete, Szabolcs
Beck, Alain
Wagner, Elsa
Vuignier, Karine
Guillarme, Davy - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The poor recovery of large biomolecules is a well‐known issue in reversed‐phase liquid chromatography. Several papers have reported this problem, but the reasons behind this behavior are not yet fully understood. In the present study, state‐of‐the‐art reversed‐phase wide‐pore stationary phases were used to evaluate the adsorption of therapeutic monoclonal antibodies. These biomolecules possess molar mass of approximately 150 000 g/mol and isoelectric points between 6.6 and 9.3. Two types of stationary phases were tested, the Phenomenex Aeris Widepore (silica based), with 3.6 μm superficially porous particles, and the Waters Acquity BEH300 (ethylene‐bridged hybrid), with 1.7 μm fully porous particles. A systematic investigation was carried out using 11 immunoglobulin G1, G2, and G4 antibodies, namely, panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, belimumab, adalimumab, denosumab, and ofatumumab. All are approved by the Food and Drug Administration and the European Medicines Agency in various therapeutic indications and are considered as reference antibodies. Several test proteins, such as human serum albumin, transferrin, apoferritin, ovalbumin, and others, possessing a molar mass between 42 000 and 443 000 g/mol were also evaluated to draw reliable conclusions. The purpose of this study was to find a correlation between the adsorption of<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The poor recovery of large biomolecules is a well‐known issue in reversed‐phase liquid chromatography. Several papers have reported this problem, but the reasons behind this behavior are not yet fully understood. In the present study, state‐of‐the‐art reversed‐phase wide‐pore stationary phases were used to evaluate the adsorption of therapeutic monoclonal antibodies. These biomolecules possess molar mass of approximately 150 000 g/mol and isoelectric points between 6.6 and 9.3. Two types of stationary phases were tested, the Phenomenex Aeris Widepore (silica based), with 3.6 μm superficially porous particles, and the Waters Acquity BEH300 (ethylene‐bridged hybrid), with 1.7 μm fully porous particles. A systematic investigation was carried out using 11 immunoglobulin G1, G2, and G4 antibodies, namely, panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, belimumab, adalimumab, denosumab, and ofatumumab. All are approved by the Food and Drug Administration and the European Medicines Agency in various therapeutic indications and are considered as reference antibodies. Several test proteins, such as human serum albumin, transferrin, apoferritin, ovalbumin, and others, possessing a molar mass between 42 000 and 443 000 g/mol were also evaluated to draw reliable conclusions. The purpose of this study was to find a correlation between the adsorption of monoclonal antibodies and their physicochemical properties. Therefore, the impact of isoelectric point, molar mass, protein glycosylation, and hydrophobicity was investigated. The adsorption of intact antibodies on the stationary phase was significantly higher than that of proteins of similar size, isoelectric point, or hydrophobicity. The present study also demonstrates the unique behavior of monoclonal antibodies, contributing some unwanted and unpredictable strong secondary interactions.</p> </abstract> … (more)
- Is Part Of:
- Journal of separation science. Volume 38:Issue 1(2015:Jan.)
- Journal:
- Journal of separation science
- Issue:
- Volume 38:Issue 1(2015:Jan.)
- Issue Display:
- Volume 38, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2015-0038-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2014-12-09
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201400996 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4077.xml