Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!. Issue 1 (9th December 2014)
- Record Type:
- Journal Article
- Title:
- Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!. Issue 1 (9th December 2014)
- Main Title:
- Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!
- Authors:
- NOF, EYAL
LANE, CHRISTOPHER
CAZALAS, MAXIME
CUCHET‐SOUBELET, ELISABETH
MICHAUD, GREGORY F.
JOHN, ROY M.
TEDROW, USHA
KOPLAN, BRUCE A.
STEVENSON, WILLIAM G.
EPSTEIN, LAURENCE M. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="pace12544-sec-0010" sec-type="section"> <title>Background</title> <p>To exposure in patients undergoing cardiac electrophysiology (EP) ablation. This included the use of a "very low" dose protocol, and the impact of angulations and patient body mass index (BMI) on radiation dose as a mean to reduce exposure.</p> </sec> <sec id="pace12544-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 212 retrospective patient data sets were collected during EP ablation procedures on a biplane fluoroscopy system. Dose metrics were computed based on dose‐area product (DAP) measured by the system for each x‐ray acquisition.</p> </sec> <sec id="pace12544-sec-0030" sec-type="section"> <title>Results</title> <p>Dose baselines of different ablation procedures were established as DAP and DAP per hour, with respect to patient BMI. The use of a "very low dose" protocol reduced exposure by 62% while providing adequate image quality. With approximate left anterior oblique (LAO) 50° and right anterior oblique (RAO) 30°, DAP and DAP rate were significantly higher in LAO compared to RAO (11.2 [4.8–25.3] Gy·cm<sup>2</sup> vs 5.28 [2.9–11.1] Gy·cm<sup>2</sup> and 74.0 [38.2–136.1] Gy·cm<sup>2</sup>/h vs 25.0 [16.4–44.1] Gy·cm<sup>2</sup>/h, respectively; P &lt; 0.001). DAP and DAP rate were also significantly higher in patients with BMI &gt; 30 vs BMI ≤ 30 (34.2 [22.3–58.7] Gy·cm<sup>2</sup> vs<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="pace12544-sec-0010" sec-type="section"> <title>Background</title> <p>To exposure in patients undergoing cardiac electrophysiology (EP) ablation. This included the use of a "very low" dose protocol, and the impact of angulations and patient body mass index (BMI) on radiation dose as a mean to reduce exposure.</p> </sec> <sec id="pace12544-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 212 retrospective patient data sets were collected during EP ablation procedures on a biplane fluoroscopy system. Dose metrics were computed based on dose‐area product (DAP) measured by the system for each x‐ray acquisition.</p> </sec> <sec id="pace12544-sec-0030" sec-type="section"> <title>Results</title> <p>Dose baselines of different ablation procedures were established as DAP and DAP per hour, with respect to patient BMI. The use of a "very low dose" protocol reduced exposure by 62% while providing adequate image quality. With approximate left anterior oblique (LAO) 50° and right anterior oblique (RAO) 30°, DAP and DAP rate were significantly higher in LAO compared to RAO (11.2 [4.8–25.3] Gy·cm<sup>2</sup> vs 5.28 [2.9–11.1] Gy·cm<sup>2</sup> and 74.0 [38.2–136.1] Gy·cm<sup>2</sup>/h vs 25.0 [16.4–44.1] Gy·cm<sup>2</sup>/h, respectively; P &lt; 0.001). DAP and DAP rate were also significantly higher in patients with BMI &gt; 30 vs BMI ≤ 30 (34.2 [22.3–58.7] Gy·cm<sup>2</sup> vs 12.4 [6.0–26.9] Gy·cm<sup>2</sup> and 84.9 [68.1–120.4] Gy·cm<sup>2</sup>/h vs 34.2 [21.7–52.9] Gy·cm<sup>2</sup>/h, respectively; P &lt; 0.001).</p> </sec> <sec id="pace12544-sec-0040" sec-type="section"> <title>Conclusion</title> <p>Protocol setting, system angulation, and BMI, in particular, wider angulation in LAO compared to RAO plane, exposes patients to significant higher radiation doses. Obese patients in standard LAO plane receive six times the radiation dose of nonobese patients in RAO.</p> </sec> </abstract> … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 38:Issue 1(2015)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 38:Issue 1(2015)
- Issue Display:
- Volume 38, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2015-0038-0001-0000
- Page Start:
- 136
- Page End:
- 145
- Publication Date:
- 2014-12-09
- Subjects:
- Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.12544 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4004.xml