Evaluation of Stroke Volume and Ventricular Mass in a Fetal Heart Model: A Novel Four‐Dimensional Echocardiographic Analysis. Issue 9 (24th January 2014)
- Record Type:
- Journal Article
- Title:
- Evaluation of Stroke Volume and Ventricular Mass in a Fetal Heart Model: A Novel Four‐Dimensional Echocardiographic Analysis. Issue 9 (24th January 2014)
- Main Title:
- Evaluation of Stroke Volume and Ventricular Mass in a Fetal Heart Model: A Novel Four‐Dimensional Echocardiographic Analysis
- Authors:
- Zhu, Meihua
Streiff, Cole
Panosian, Jill
Roundhill, David
Lapin, Michael
Tutschek, Boris
Ashraf, Muhammad
Sahn, David J. - Abstract:
- <abstract abstract-type="main" id="echo12520-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12520-sec-0001" sec-type="section"> <title>Aims</title> <p>This study aimed to assess the feasibility and accuracy of nongated four‐dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart‐sized LV model.</p> </sec> <sec id="echo12520-sec-0002" sec-type="section"> <title>Methods</title> <p>A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU‐22 system with an X6‐1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end‐systole and end‐diastole. Mass was determined by displacement at the conclusion of the experiment.</p> </sec> <sec id="echo12520-sec-0003" sec-type="section"> <title>Results</title> <p>The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo‐derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R<sup>2</sup>) in both groups (SV: Group A: R<sup>2</sup> = 0.9461, Group B: R<sup>2</sup> = 0.9811;<abstract abstract-type="main" id="echo12520-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="echo12520-sec-0001" sec-type="section"> <title>Aims</title> <p>This study aimed to assess the feasibility and accuracy of nongated four‐dimensional echocardiography (4DE) for determining left ventricular (LV) stroke volume (SV) and mass in a fetal heart‐sized LV model.</p> </sec> <sec id="echo12520-sec-0002" sec-type="section"> <title>Methods</title> <p>A balloon was inserted into the LV of 20 fresh rabbit hearts and attached to a calibrated pulsatile pump. Ten hearts retaining the right ventricle were imaged in Group A. Ten hearts without the right ventricles (RVs) attached were imaged in Group B. Nongated 4D volumes were obtained using a Philips iU‐22 system with an X6‐1 matrix probe at SVs ranging from 1 to 5 mL at increments of 1 mL. At each SV, the volume displacement of the heart was measured at end‐systole and end‐diastole. Mass was determined by displacement at the conclusion of the experiment.</p> </sec> <sec id="echo12520-sec-0003" sec-type="section"> <title>Results</title> <p>The images were analyzed offline by manually tracing endocardial and epicardial boundaries of stacked contours. An excellent correlation in SV and mass between echo‐derived values and displacement values was demonstrated and accompanied by high coefficients of determination (R<sup>2</sup>) in both groups (SV: Group A: R<sup>2</sup> = 0.9461, Group B: R<sup>2</sup> = 0.9811; Mass: Group A: R<sup>2</sup> = 0.9223, Group B: R<sup>2</sup> = 0.9602; all P &lt; 0.001). Bland–Altman analyses showed a slight overestimation in both groups for both SV and LV mass.</p> </sec> <sec id="echo12520-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Nongated 4DE was demonstrated to be feasible and that it could accurately define SV and ventricular mass for a fetal heart‐sized LV model.</p> </sec> </abstract> … (more)
- Is Part Of:
- Echocardiography. Volume 31:Issue 9(2014)
- Journal:
- Echocardiography
- Issue:
- Volume 31:Issue 9(2014)
- Issue Display:
- Volume 31, Issue 9 (2014)
- Year:
- 2014
- Volume:
- 31
- Issue:
- 9
- Issue Sort Value:
- 2014-0031-0009-0000
- Page Start:
- 1138
- Page End:
- 1145
- Publication Date:
- 2014-01-24
- Subjects:
- Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12520 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3673.xml