Feasibility and safety of a virtual 3‐Fr sheathless‐guiding system for percutaneous coronary intervention. Issue 3 (4th February 2014)
- Record Type:
- Journal Article
- Title:
- Feasibility and safety of a virtual 3‐Fr sheathless‐guiding system for percutaneous coronary intervention. Issue 3 (4th February 2014)
- Main Title:
- Feasibility and safety of a virtual 3‐Fr sheathless‐guiding system for percutaneous coronary intervention
- Authors:
- Tonomura, Daisuke
Shimada, Yoshihisa
Yano, Kentaro
Ito, Kazato
Takehara, Kosuke
Kino, Naoto
Furubayashi, Keiichi
Kurotobi, Toshiya
Tsuchida, Takao
Fukumoto, Hitoshi - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25357-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the feasibility and safety of a virtual 3‐Fr system [5‐Fr sheathless‐guiding catheter (GC)] for percutaneous coronary intervention (PCI).</p> </sec> <sec id="ccd25357-sec-0002" sec-type="section"> <title>Background</title> <p>The use of miniaturized devices for PCI is gaining popularity because of increased patient comfort and decreased risk of access site complications.</p> </sec> <sec id="ccd25357-sec-0003" sec-type="section"> <title>Methods</title> <p>From July 2010 to December 2012, consecutive patients who underwent elective PCI (planned or ad hoc PCI) at our hospital were enrolled. PCI using the virtual 3‐Fr system was attempted as our initial strategy, unless a 6‐Fr or larger GC was considered to be suitable [lesions with heavy calcification, large (&gt;2 mm) side branches, or chronic total occlusion].</p> </sec> <sec id="ccd25357-sec-0004" sec-type="section"> <title>Results</title> <p>Five hundred sixty‐six patients underwent elective PCI during the study period, and 132 patients who met the criteria underwent PCI using the virtual 3‐Fr system. Procedures using the virtual 3‐Fr system were successful in 126 patients (95%); 111 (84%) were performed using the transradial approach, 110 (83%) were ad hoc procedures, and 45 (31%) were complex coronary lesions (type B2 or C). Six patients required<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25357-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the feasibility and safety of a virtual 3‐Fr system [5‐Fr sheathless‐guiding catheter (GC)] for percutaneous coronary intervention (PCI).</p> </sec> <sec id="ccd25357-sec-0002" sec-type="section"> <title>Background</title> <p>The use of miniaturized devices for PCI is gaining popularity because of increased patient comfort and decreased risk of access site complications.</p> </sec> <sec id="ccd25357-sec-0003" sec-type="section"> <title>Methods</title> <p>From July 2010 to December 2012, consecutive patients who underwent elective PCI (planned or ad hoc PCI) at our hospital were enrolled. PCI using the virtual 3‐Fr system was attempted as our initial strategy, unless a 6‐Fr or larger GC was considered to be suitable [lesions with heavy calcification, large (&gt;2 mm) side branches, or chronic total occlusion].</p> </sec> <sec id="ccd25357-sec-0004" sec-type="section"> <title>Results</title> <p>Five hundred sixty‐six patients underwent elective PCI during the study period, and 132 patients who met the criteria underwent PCI using the virtual 3‐Fr system. Procedures using the virtual 3‐Fr system were successful in 126 patients (95%); 111 (84%) were performed using the transradial approach, 110 (83%) were ad hoc procedures, and 45 (31%) were complex coronary lesions (type B2 or C). Six patients required conversion to a conventional 5‐ or 6‐Fr sheath and catheter system. No intraoperative complications occurred, and radial artery patency was achieved in all patients who underwent transradial procedures.</p> </sec> <sec id="ccd25357-sec-0005" sec-type="section"> <title>Conclusions</title> <p>PCI using the virtual 3‐Fr system is a feasible and viable alternative to conventional procedures that use a sheath and GC in appropriately selected patients. This small‐caliber system may minimize endovascular trauma, particularly during transradial coronary procedures. © 2014 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 84:Issue 3(2014:Sep. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 84:Issue 3(2014:Sep. 01)
- Issue Display:
- Volume 84, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 84
- Issue:
- 3
- Issue Sort Value:
- 2014-0084-0003-0000
- Page Start:
- 426
- Page End:
- 435
- Publication Date:
- 2014-02-04
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25357 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4211.xml