Effect of Implant Angulation on Attachment Retention in Mandibular Two‐Implant Overdentures: A Clinical Study. (10th January 2013)
- Record Type:
- Journal Article
- Title:
- Effect of Implant Angulation on Attachment Retention in Mandibular Two‐Implant Overdentures: A Clinical Study. (10th January 2013)
- Main Title:
- Effect of Implant Angulation on Attachment Retention in Mandibular Two‐Implant Overdentures: A Clinical Study
- Authors:
- Jabbour, Zaher
Fromentin, Olivier
Lassauzay, Claire
Abi Nader, Samer
Correa, José A.
Feine, Jocelyne
de Albuquerque Junior, Rubens F. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12030-sec-0001" sec-type="section"> <title>Purpose</title> <p>Attachment wear can affect the performance of mandibular two‐implant overdentures (IODs). This prospective clinical study aimed to investigate the effect of interimplant angulation on the retention achieved by two attachment systems at different time points within 1 year of wearing IODs.</p> </sec> <sec id="cid12030-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Twenty‐four patients (mean age = 73.2 years; standard deviation (SD) = 3.1) wearing IODs opposed by conventional maxillary complete dentures were randomly assigned to two groups in two‐by‐two crossover design. Retentive Anchor (RA) and Locator (LA) were installed in the IODs of both groups for 1 year, sequentially. Coronal and sagittal interimplant angulation were measured on posterior–anterior and lateral cephalometric radiographs. Retention was measured at baseline, 1 week, 3, 6, and 12 months postattachment installation. Data were analyzed using mixed models with α = 0.05.</p> </sec> <sec id="cid12030-sec-0003" sec-type="section"> <title>Results</title> <p>Mean coronal and sagittal interimplant angulations were 4.6 (SD = 2.9) and 3.5 (SD = 2.6) degrees, respectively. Only with LAs a statistically significant decrease was found in retention (average 1.1 Newton; standard error = 0.38; <italic>p</italic> = .007) per 1 degree increased sagittal interimplant<abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12030-sec-0001" sec-type="section"> <title>Purpose</title> <p>Attachment wear can affect the performance of mandibular two‐implant overdentures (IODs). This prospective clinical study aimed to investigate the effect of interimplant angulation on the retention achieved by two attachment systems at different time points within 1 year of wearing IODs.</p> </sec> <sec id="cid12030-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Twenty‐four patients (mean age = 73.2 years; standard deviation (SD) = 3.1) wearing IODs opposed by conventional maxillary complete dentures were randomly assigned to two groups in two‐by‐two crossover design. Retentive Anchor (RA) and Locator (LA) were installed in the IODs of both groups for 1 year, sequentially. Coronal and sagittal interimplant angulation were measured on posterior–anterior and lateral cephalometric radiographs. Retention was measured at baseline, 1 week, 3, 6, and 12 months postattachment installation. Data were analyzed using mixed models with α = 0.05.</p> </sec> <sec id="cid12030-sec-0003" sec-type="section"> <title>Results</title> <p>Mean coronal and sagittal interimplant angulations were 4.6 (SD = 2.9) and 3.5 (SD = 2.6) degrees, respectively. Only with LAs a statistically significant decrease was found in retention (average 1.1 Newton; standard error = 0.38; <italic>p</italic> = .007) per 1 degree increased sagittal interimplant angulation.</p> </sec> <sec id="cid12030-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Increased interimplant angulation appears to have higher impact on the retention of LA than of RA attachments. The effect of larger interimplant angulation on the loss of attachment retention and its clinical implications should be further assessed.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 16:Number 4(2014:Nov.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 16:Number 4(2014:Nov.)
- Issue Display:
- Volume 16, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 16
- Issue:
- 4
- Issue Sort Value:
- 2014-0016-0004-0000
- Page Start:
- 565
- Page End:
- 571
- Publication Date:
- 2013-01-10
- Subjects:
- Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/cid.12030 ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3241.xml