Histopathological differences between prostate cancer foci that are detected and missed using multiparametric magnetic resonance imaging in Korean patients. (8th November 2013)
- Record Type:
- Journal Article
- Title:
- Histopathological differences between prostate cancer foci that are detected and missed using multiparametric magnetic resonance imaging in Korean patients. (8th November 2013)
- Main Title:
- Histopathological differences between prostate cancer foci that are detected and missed using multiparametric magnetic resonance imaging in Korean patients
- Authors:
- Chung, Jae Dong
Lee, Jong Beum
Lee, Tae‐Jin
Kwon, Jong Kyou
Kim, Jung Hoon
Chang, In Ho
Kim, Kyung Do - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="iju12331-sec-0001" sec-type="section"> <title>Objectives</title> <p>We investigated whether multiparametric magnetic resonance imaging is appropriate to localize prostate cancer foci in Koreans.</p> </sec> <sec id="iju12331-sec-0002" sec-type="section"> <title>Methods</title> <p>A total of 141 prostate cancer foci in 115 prostate specimens from patients who had undergone radical prostatectomy with preoperative 3 Tesla multiparametric magnetic resonance imaging including T2‐weighted imaging, diffusion weighted imaging and magnetic resonance spectroscopy. Differences in the histopathological findings between detected and undetected prostate cancer foci on multiparametric magnetic resonance imaging were investigated.</p> </sec> <sec id="iju12331-sec-0003" sec-type="section"> <title>Results</title> <p>The mean tumor size was 1.9 cm, and 31.9%, 48.9%, and 19.9% of the patients had Gleason scores of 6, 7, or ≥8, respectively. The detection rates of prostate cancer foci were 54.6%, 57.4%, 55.3%, and 45.4% on multiparametric magnetic resonance imaging, T2‐weighted imaging, diffusion weighted imaging, and magnetic resonance spectroscopy, respectively. On multivariate analysis, tumor size ≥1.5 cm (odds ratio 3.1; 95% confidence interval 1.31–7.49), Gleason score &gt;7 (4 + 3; odds ratio 2.9; 95% confidence interval 1.05–8.05), and a malignant epithelium/stroma ratio of ≥60% (odds ratio 2.9;<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="iju12331-sec-0001" sec-type="section"> <title>Objectives</title> <p>We investigated whether multiparametric magnetic resonance imaging is appropriate to localize prostate cancer foci in Koreans.</p> </sec> <sec id="iju12331-sec-0002" sec-type="section"> <title>Methods</title> <p>A total of 141 prostate cancer foci in 115 prostate specimens from patients who had undergone radical prostatectomy with preoperative 3 Tesla multiparametric magnetic resonance imaging including T2‐weighted imaging, diffusion weighted imaging and magnetic resonance spectroscopy. Differences in the histopathological findings between detected and undetected prostate cancer foci on multiparametric magnetic resonance imaging were investigated.</p> </sec> <sec id="iju12331-sec-0003" sec-type="section"> <title>Results</title> <p>The mean tumor size was 1.9 cm, and 31.9%, 48.9%, and 19.9% of the patients had Gleason scores of 6, 7, or ≥8, respectively. The detection rates of prostate cancer foci were 54.6%, 57.4%, 55.3%, and 45.4% on multiparametric magnetic resonance imaging, T2‐weighted imaging, diffusion weighted imaging, and magnetic resonance spectroscopy, respectively. On multivariate analysis, tumor size ≥1.5 cm (odds ratio 3.1; 95% confidence interval 1.31–7.49), Gleason score &gt;7 (4 + 3; odds ratio 2.9; 95% confidence interval 1.05–8.05), and a malignant epithelium/stroma ratio of ≥60% (odds ratio 2.9; 95% confidence interval 1.14–7.20) were significant independent predictors of prostate cancer foci detection on multiparametric magnetic resonance imaging and diffusion weighted imaging. In a multivariate linear model analysis, the apparent diffusion coefficient value was inversely associated with maximum tumor diameter (β = −0.242, <italic>P</italic> &lt; 0.05), Gleason score (β = −0.234, <italic>P</italic> &lt; 0.05) and high malignant epithelium/stroma ratio (β = −0.229, <italic>P</italic> &lt; 0.05).</p> </sec> <sec id="iju12331-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Distinct histological differences between prostate cancer foci that were detected and missed by multiparametric magnetic resonance imaging can be identified. Despite limitations, multiparametric magnetic resonance imaging seems useful for determining prostate cancer in Korean patients, particularly with Gleason score &gt;7 and tumor diameter &gt;1.5 cm.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of urology. Volume 21:Number 5(2014)
- Journal:
- International journal of urology
- Issue:
- Volume 21:Number 5(2014)
- Issue Display:
- Volume 21, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2014-0021-0005-0000
- Page Start:
- 466
- Page End:
- 472
- Publication Date:
- 2013-11-08
- Subjects:
- Urology -- Periodicals
Genitourinary organs -- Periodicals
Urologic Diseases -- Periodicals
616.6005 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=iju ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/iju.12331 ↗
- Languages:
- English
- ISSNs:
- 0919-8172
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.697100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4194.xml