Comparison between microcomputed tomography and cone‐beam computed tomography radiologic bone to assess atrophic posterior maxilla density and microarchitecture. Issue 6 (26th February 2013)
- Record Type:
- Journal Article
- Title:
- Comparison between microcomputed tomography and cone‐beam computed tomography radiologic bone to assess atrophic posterior maxilla density and microarchitecture. Issue 6 (26th February 2013)
- Main Title:
- Comparison between microcomputed tomography and cone‐beam computed tomography radiologic bone to assess atrophic posterior maxilla density and microarchitecture
- Authors:
- Monje, Alberto
Monje, Florencio
González‐García, Raúl
Galindo‐Moreno, Pablo
Rodriguez‐Salvanes, Francisco
Wang, Hom‐Lay - Abstract:
- <abstract abstract-type="main" id="clr12133-abs-0001"> <title>Abstract</title> <sec id="clr12133-sec-0001" sec-type="section"> <title>Purpose</title> <p>The aim of this study was to analyze the relationship between bone density obtained by cone‐beam computed tomography (CBCT) and morphometric parameters of bone analyzed by microcomputed tomography (μ‐CT).</p> </sec> <sec id="clr12133-sec-0002" sec-type="section"> <title>Material and methods</title> <p>An overall of 32 subjects ≤8 mm of bone height were included in the study. One site per patient was randomly selected to obtain bone core. Totally, 27 biopsies were available for μ‐CT analysis. In addition, CBCT was taken after positioning a previously fabricated acrylic resin template with a 2‐mm‐diameter metal rod at the randomly selected implant site to study radiographic bone density (RBD). The relationship between μ‐CT and CBCT quantitative variable and RBD was analyzed using Spearman correlation.</p> </sec> <sec id="clr12133-sec-0003" sec-type="section"> <title>Results</title> <p>Positive correlations between BV/TV (<italic>r</italic> = 0.769, <italic>P</italic> &lt; 0.001), BS/TV (<italic>r</italic> = 0.563, <italic>P</italic> = 0.002), Tb.Th (<italic>r</italic> = 0.491, <italic>P</italic> = 0.009), Tb.N (<italic>r</italic> = 0.518, <italic>P</italic> = 0.005) and vBMD (<italic>r</italic> = 0.699, <italic>P</italic> &lt; 0.001) with RBD were identified. On the contrary, BS/BV (<italic>r</italic> = −0.509,<abstract abstract-type="main" id="clr12133-abs-0001"> <title>Abstract</title> <sec id="clr12133-sec-0001" sec-type="section"> <title>Purpose</title> <p>The aim of this study was to analyze the relationship between bone density obtained by cone‐beam computed tomography (CBCT) and morphometric parameters of bone analyzed by microcomputed tomography (μ‐CT).</p> </sec> <sec id="clr12133-sec-0002" sec-type="section"> <title>Material and methods</title> <p>An overall of 32 subjects ≤8 mm of bone height were included in the study. One site per patient was randomly selected to obtain bone core. Totally, 27 biopsies were available for μ‐CT analysis. In addition, CBCT was taken after positioning a previously fabricated acrylic resin template with a 2‐mm‐diameter metal rod at the randomly selected implant site to study radiographic bone density (RBD). The relationship between μ‐CT and CBCT quantitative variable and RBD was analyzed using Spearman correlation.</p> </sec> <sec id="clr12133-sec-0003" sec-type="section"> <title>Results</title> <p>Positive correlations between BV/TV (<italic>r</italic> = 0.769, <italic>P</italic> &lt; 0.001), BS/TV (<italic>r</italic> = 0.563, <italic>P</italic> = 0.002), Tb.Th (<italic>r</italic> = 0.491, <italic>P</italic> = 0.009), Tb.N (<italic>r</italic> = 0.518, <italic>P</italic> = 0.005) and vBMD (<italic>r</italic> = 0.699, <italic>P</italic> &lt; 0.001) with RBD were identified. On the contrary, BS/BV (<italic>r</italic> = −0.509, <italic>P</italic> = 0.006), Tb.Sp (<italic>r</italic> = −0.539, <italic>P</italic> = 0.003) and Tb.Pf (<italic>r</italic> = −0.636, <italic>P</italic> &lt; 0.001) were negatively correlated with RBD. Moreover, SMI (<italic>r</italic> = −0.380, <italic>P</italic> = 0.050) and DA (−0.245, <italic>P</italic> = 0.217) were negatively correlated but not statistically significant.</p> </sec> <sec id="clr12133-sec-0004" sec-type="section"> <title>Conclusion</title> <p>This study demonstrated the correlation between radiographic bone density (RBD) and bone density assessed by μ‐CT. Therefore, our data supported the use of CBCT as pre‐operative tool for implant treatment planning because it is shown to be reliable to assess atrophic posterior maxilla density and microarchitecture.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 25:Issue 6(2014:Jun.)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 25:Issue 6(2014:Jun.)
- Issue Display:
- Volume 25, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 6
- Issue Sort Value:
- 2014-0025-0006-0000
- Page Start:
- 723
- Page End:
- 728
- Publication Date:
- 2013-02-26
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12133 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4184.xml