Automated non‐stepwise preparation of bioanalytical calibration standards and quality controls using an ultra‐low volume digitizing liquid dispenser. (15th June 2014)
- Record Type:
- Journal Article
- Title:
- Automated non‐stepwise preparation of bioanalytical calibration standards and quality controls using an ultra‐low volume digitizing liquid dispenser. (15th June 2014)
- Main Title:
- Automated non‐stepwise preparation of bioanalytical calibration standards and quality controls using an ultra‐low volume digitizing liquid dispenser
- Authors:
- Liao, Debra
Chen, Susan
Paton, Martin
Qian, Mark G. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6894-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>Stepwise preparation of calibration standards and quality controls (QCs) is one of the most routine and laborious steps in bioanalysis. An alternative non‐contact dispenser using low picoliter digitized dispensing technology is evaluated for its application in non‐stepwise preparation of calibration curve and QCs in bioanalysis.</p> </sec> <sec id="rcm6894-sec-0002" sec-type="section"> <title>METHODS</title> <p>Fluorescein was initially used to assess the accuracy and precision of dispense volumes with fluorescent measurement. Various concentrations of MX‐1, an in‐house proprietary small molecule compound, in neat solution and in dog plasma were prepared manually with calibrated pipettors and digitally by the digital dispenser. The plasma samples were extracted by protein precipitation. The resultant extracted samples and neat solutions of MX‐1 were analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using an electrospray ionization (ESI) source in positive ion mode with selected reaction monitoring (SRM) of the mass transitions.</p> </sec> <sec id="rcm6894-sec-0003" sec-type="section"> <title>RESULTS</title> <p>In the three‐day precision and accuracy assessment of dispensing volumes between 13 pL to 411.2 nL, the intra‐day precision and accuracy ranged from 1.4% to 10.3% and –12.7% to 12.8%,<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6894-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>Stepwise preparation of calibration standards and quality controls (QCs) is one of the most routine and laborious steps in bioanalysis. An alternative non‐contact dispenser using low picoliter digitized dispensing technology is evaluated for its application in non‐stepwise preparation of calibration curve and QCs in bioanalysis.</p> </sec> <sec id="rcm6894-sec-0002" sec-type="section"> <title>METHODS</title> <p>Fluorescein was initially used to assess the accuracy and precision of dispense volumes with fluorescent measurement. Various concentrations of MX‐1, an in‐house proprietary small molecule compound, in neat solution and in dog plasma were prepared manually with calibrated pipettors and digitally by the digital dispenser. The plasma samples were extracted by protein precipitation. The resultant extracted samples and neat solutions of MX‐1 were analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using an electrospray ionization (ESI) source in positive ion mode with selected reaction monitoring (SRM) of the mass transitions.</p> </sec> <sec id="rcm6894-sec-0003" sec-type="section"> <title>RESULTS</title> <p>In the three‐day precision and accuracy assessment of dispensing volumes between 13 pL to 411.2 nL, the intra‐day precision and accuracy ranged from 1.4% to 10.3% and –12.7% to 12.8%, respectively. The inter‐day precision and accuracy ranged from 3.5% to 7.8% and –6.6% to 10.4%, respectively. For real analysis of <italic>in vivo</italic> study samples, all 49 samples analyzed showed a less than 5% difference between calibrations with digital and manual curve preparations. The resultant pharmacokinetic (PK) parameters were physiologically comparable as well.</p> </sec> <sec id="rcm6894-sec-0004" sec-type="section"> <title>CONCLUSIONS</title> <p>Using the digitized picoliter dispensing technology, high‐speed automated precise and accurate dispense of a wide range of volumes can be achieved and tests for bioanalytical standards and QC preparations passed the stringent criteria set forth for regulated bioanalysis using LC/MS/MS‐based technology. The digital dispenser has been found to be a useful tool in drug discovery for automatically preparing standards and QCs in seconds with low consumption of stock solutions and blank matrices. Copyright © 2014 John Wiley &amp; Sons, Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 28:Number 11(2014)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 28:Number 11(2014)
- Issue Display:
- Volume 28, Issue 11 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 11
- Issue Sort Value:
- 2014-0028-0011-0000
- Page Start:
- 1215
- Page End:
- 1220
- Publication Date:
- 2014-06-15
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.6894 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4334.xml