Decreased FEV1% in asthmatic adults in Scottish homes with high Environmental Relative Moldiness Index values. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- Decreased FEV1% in asthmatic adults in Scottish homes with high Environmental Relative Moldiness Index values. Issue 5 (May 2015)
- Main Title:
- Decreased FEV1% in asthmatic adults in Scottish homes with high Environmental Relative Moldiness Index values
- Authors:
- McSharry, C.
Vesper, S.
Wymer, L.
Howieson, S.
Chaudhuri, R.
Wright, G. R.
Thomson, N. C. - Abstract:
- <abstract abstract-type="main" id="cea12482-abs-0001"> <title>Summary</title> <sec id="cea12482-sec-0001" sec-type="section"> <title>Background</title> <p>Exposures to indoor biological contaminants have been implicated in asthma's aetiology but their effect on lung function is not well quantified.</p> </sec> <sec id="cea12482-sec-0002" sec-type="section"> <title>Objective</title> <p>The aim of this cross‐sectional study of non‐smoking, asthmatic adults in Scotland was to determine the correlation between the results from a standard spirometry test, forced expiratory volume in one‐second percent (FEV<sub>1</sub>%), and quantitative estimates of some biological exposures.</p> </sec> <sec id="cea12482-sec-0003" sec-type="section"> <title>Methods</title> <p>A population (<italic>n</italic> = 55) of non‐smoking, adult asthmatics in Scotland was included in this study and each completed a questionnaire that allowed the determination of the Asthma Control Questionnaire scores (ACQ) and St. George's Respiratory Questionnaire scores (SGRQ), as well as corticosteroid use. Spirometry testing was completed and the pre‐bronchodilator FEV<sub>1</sub>% value calculated. At about the same time, floor dust samples were collected in the living room and in the bedroom. These dust samples were analysed for mould contamination, as described by the Environmental Relative Moldiness Index (ERMI) values and by (1, 3)‐β‐D‐glucan concentrations, for endotoxin, and for dust mite, cat, and dog allergen<abstract abstract-type="main" id="cea12482-abs-0001"> <title>Summary</title> <sec id="cea12482-sec-0001" sec-type="section"> <title>Background</title> <p>Exposures to indoor biological contaminants have been implicated in asthma's aetiology but their effect on lung function is not well quantified.</p> </sec> <sec id="cea12482-sec-0002" sec-type="section"> <title>Objective</title> <p>The aim of this cross‐sectional study of non‐smoking, asthmatic adults in Scotland was to determine the correlation between the results from a standard spirometry test, forced expiratory volume in one‐second percent (FEV<sub>1</sub>%), and quantitative estimates of some biological exposures.</p> </sec> <sec id="cea12482-sec-0003" sec-type="section"> <title>Methods</title> <p>A population (<italic>n</italic> = 55) of non‐smoking, adult asthmatics in Scotland was included in this study and each completed a questionnaire that allowed the determination of the Asthma Control Questionnaire scores (ACQ) and St. George's Respiratory Questionnaire scores (SGRQ), as well as corticosteroid use. Spirometry testing was completed and the pre‐bronchodilator FEV<sub>1</sub>% value calculated. At about the same time, floor dust samples were collected in the living room and in the bedroom. These dust samples were analysed for mould contamination, as described by the Environmental Relative Moldiness Index (ERMI) values and by (1, 3)‐β‐D‐glucan concentrations, for endotoxin, and for dust mite, cat, and dog allergen concentrations. The asthmatics' FEV<sub>1</sub>% values were tested for correlation (Pearson) to questionnaire‐based estimates of health. Also, each biological exposure was tested for correlation (Pearson) to the FEV<sub>1</sub>% values.</p> </sec> <sec id="cea12482-sec-0004" sec-type="section"> <title>Results</title> <p>FEV<sub>1</sub>% results were correlated with ACQ scores (ρ −0.586, <italic>P</italic> &lt; 0.001), SGRQ scores (ρ −0.313, <italic>P</italic> = 0.020), and weakly with corticosteroid use (ρ −0.221, <italic>P</italic> = 0.105). The ERMI values in the homes (average 5.3) were significantly correlated with FEV<sub>1</sub>% values (ρ −0.378, <italic>P</italic> = 0.004). There was no correlation between FEV<sub>1</sub>% and concentrations of endotoxin, (1, 3)‐β‐D‐glucan, or any of the allergens.</p> </sec> <sec id="cea12482-sec-0005" sec-type="section"> <title>Conclusion and clinical relevance</title> <p>Although these results do not prove that mould exposures caused the deficit in lung function observed in this study, it might be advisable for asthmatics to avoid high ERMI environments.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical & experimental allergy. Volume 45:Issue 5(2015:May)
- Journal:
- Clinical & experimental allergy
- Issue:
- Volume 45:Issue 5(2015:May)
- Issue Display:
- Volume 45, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2015-0045-0005-0000
- Page Start:
- 902
- Page End:
- 907
- Publication Date:
- 2015-05
- Subjects:
- Allergy -- Periodicals
Immunology -- Periodicals
616.97 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0954-7894&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2222 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cea.12482 ↗
- Languages:
- English
- ISSNs:
- 0954-7894
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.249700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3803.xml