Repositioning precision of coronary arteries measured on X‐ray angiography and its implications for coronary MR angiography. Issue 5 (3rd July 2014)
- Record Type:
- Journal Article
- Title:
- Repositioning precision of coronary arteries measured on X‐ray angiography and its implications for coronary MR angiography. Issue 5 (3rd July 2014)
- Main Title:
- Repositioning precision of coronary arteries measured on X‐ray angiography and its implications for coronary MR angiography
- Authors:
- Coppo, Simone
Firsova, Maria
Locca, Didier
Knebel, Jean‐François
van Heeswijk, Ruud B.
Stuber, Matthias - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24685-sec-0001" sec-type="section"> <title>Background</title> <p>To test the hypothesis that intervals with superior beat‐to‐beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance.</p> </sec> <sec id="jmri24685-sec-0002" sec-type="section"> <title>Methods</title> <p>Coronary repositioning precision in consecutive heartbeats was measured on x‐ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T<sub>2</sub>‐prep now follows (T<sub>2</sub>‐post) rather than precedes the imaging part of the sequence. The performance of T<sub>2</sub>‐post was quantitatively compared (signal‐to‐noise [SNR], contrast‐to‐noise [CNR], vessel sharpness) to that of T<sub>2</sub>‐prep in vivo.</p> </sec> <sec id="jmri24685-sec-1002" sec-type="section"> <title>Results</title> <p>Coronary repositioning precision is &lt;1 mm at peak systole and in mid diastole. When comparing systolic T<sub>2</sub>‐post to diastolic T<sub>2</sub>‐prep, CNR and vessel sharpness remained unchanged (both <italic>P</italic> = NS) but SNR for muscle and blood increased by 104% and 36% (both <italic>P</italic> &lt; 0.05), respectively.</p> </sec> <sec<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24685-sec-0001" sec-type="section"> <title>Background</title> <p>To test the hypothesis that intervals with superior beat‐to‐beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance.</p> </sec> <sec id="jmri24685-sec-0002" sec-type="section"> <title>Methods</title> <p>Coronary repositioning precision in consecutive heartbeats was measured on x‐ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T<sub>2</sub>‐prep now follows (T<sub>2</sub>‐post) rather than precedes the imaging part of the sequence. The performance of T<sub>2</sub>‐post was quantitatively compared (signal‐to‐noise [SNR], contrast‐to‐noise [CNR], vessel sharpness) to that of T<sub>2</sub>‐prep in vivo.</p> </sec> <sec id="jmri24685-sec-1002" sec-type="section"> <title>Results</title> <p>Coronary repositioning precision is &lt;1 mm at peak systole and in mid diastole. When comparing systolic T<sub>2</sub>‐post to diastolic T<sub>2</sub>‐prep, CNR and vessel sharpness remained unchanged (both <italic>P</italic> = NS) but SNR for muscle and blood increased by 104% and 36% (both <italic>P</italic> &lt; 0.05), respectively.</p> </sec> <sec id="jmri24685-sec-0003" sec-type="section"> <title>Conclusion</title> <p>Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak‐systolic imaging necessitates a re‐design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid‐diastolic data acquisition but improved SNR. <bold>J. Magn. Reson. Imaging 2015;41:1251–1258.</bold> © <bold>2014 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 41:Issue 5(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 41:Issue 5(2015)
- Issue Display:
- Volume 41, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 5
- Issue Sort Value:
- 2015-0041-0005-0000
- Page Start:
- 1251
- Page End:
- 1258
- Publication Date:
- 2014-07-03
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24685 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3608.xml