Dynamic contrast‐enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden‐angle radial sampling: Preliminary experience. Issue 5 (16th May 2014)
- Record Type:
- Journal Article
- Title:
- Dynamic contrast‐enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden‐angle radial sampling: Preliminary experience. Issue 5 (16th May 2014)
- Main Title:
- Dynamic contrast‐enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden‐angle radial sampling: Preliminary experience
- Authors:
- Rosenkrantz, Andrew B.
Geppert, Christian
Grimm, Robert
Block, Tobias K.
Glielmi, Christian
Feng, Li
Otazo, Ricardo
Ream, Justin M.
Romolo, Melanie Moccaldi
Taneja, Samir S.
Sodickson, Daniel K.
Chandarana, Hersh - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24661-sec-0001" sec-type="section"> <title>Purpose</title> <p>To demonstrate dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) of the prostate with both high spatial and temporal resolution via a combination of golden‐angle radial <italic>k</italic>‐space sampling, compressed sensing, and parallel‐imaging reconstruction (GRASP), and to compare image quality and lesion depiction between GRASP and conventional DCE in prostate cancer patients.</p> </sec> <sec id="jmri24661-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Twenty prostate cancer patients underwent two 3T prostate MRI examinations on separate dates, one using standard DCE (spatial resolution 3.0 × 1.9 × 1.9 mm, temporal resolution 5.5 sec) and the other using GRASP (spatial resolution 3.0 × 1.1 × 1.1 mm, temporal resolution 2.3 sec). Two radiologists assessed measures of image quality and dominant lesion size. The experienced reader recorded differences in contrast arrival times between the dominant lesion and benign prostate.</p> </sec> <sec id="jmri24661-sec-0003" sec-type="section"> <title>Results</title> <p>Compared with standard DCE, GRASP demonstrated significantly better clarity of the capsule, peripheral/transition zone boundary, urethra, and periprostatic vessels; image sharpness; and lesion conspicuity for both readers (<italic>P</italic> &lt; 0.001–0.020). GRASP showed<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24661-sec-0001" sec-type="section"> <title>Purpose</title> <p>To demonstrate dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) of the prostate with both high spatial and temporal resolution via a combination of golden‐angle radial <italic>k</italic>‐space sampling, compressed sensing, and parallel‐imaging reconstruction (GRASP), and to compare image quality and lesion depiction between GRASP and conventional DCE in prostate cancer patients.</p> </sec> <sec id="jmri24661-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Twenty prostate cancer patients underwent two 3T prostate MRI examinations on separate dates, one using standard DCE (spatial resolution 3.0 × 1.9 × 1.9 mm, temporal resolution 5.5 sec) and the other using GRASP (spatial resolution 3.0 × 1.1 × 1.1 mm, temporal resolution 2.3 sec). Two radiologists assessed measures of image quality and dominant lesion size. The experienced reader recorded differences in contrast arrival times between the dominant lesion and benign prostate.</p> </sec> <sec id="jmri24661-sec-0003" sec-type="section"> <title>Results</title> <p>Compared with standard DCE, GRASP demonstrated significantly better clarity of the capsule, peripheral/transition zone boundary, urethra, and periprostatic vessels; image sharpness; and lesion conspicuity for both readers (<italic>P</italic> &lt; 0.001–0.020). GRASP showed improved interreader correlation for lesion size (GRASP: <italic>r</italic> = 0.691–0.824, standard: <italic>r</italic> = 0.495–0.542). In 8/20 cases, only GRASP showed earlier contrast arrival in tumor than benign; in no case did only standard DCE show earlier contrast arrival in tumor.</p> </sec> <sec id="jmri24661-sec-0004" sec-type="section"> <title>Conclusion</title> <p>High spatiotemporal resolution prostate DCE is possible with GRASP, which has the potential to improve image quality and lesion depiction as compared with standard DCE. <bold>J. Magn. Reson. Imaging 2015;41:1365–1373.</bold> © <bold>2014 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 41:Issue 5(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 41:Issue 5(2015)
- Issue Display:
- Volume 41, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 5
- Issue Sort Value:
- 2015-0041-0005-0000
- Page Start:
- 1365
- Page End:
- 1373
- Publication Date:
- 2014-05-16
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24661 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3607.xml