The evaluation of a new apheresis device for automated red blood cell exchange procedures in patients with sickle cell disease. Issue 4 (21st October 2014)
- Record Type:
- Journal Article
- Title:
- The evaluation of a new apheresis device for automated red blood cell exchange procedures in patients with sickle cell disease. Issue 4 (21st October 2014)
- Main Title:
- The evaluation of a new apheresis device for automated red blood cell exchange procedures in patients with sickle cell disease
- Authors:
- Quirolo, Keith
Bertolone, Salvatore
Hassell, Kathryn
Howard, Thomas
King, Karen E.
Rhodes, Diane K.
Bill, Jerry - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12891-sec-0001" sec-type="section"> <title>Background</title> <p>The Spectra Optia apheresis system (SO), a blood component separator, can be used to perform red blood cell exchange (RBCX) procedures for the transfusion management of sickle cell disease (SCD) in adults and children. This study was designed to evaluate the performance of the SO RBCX protocols (exchange and depletion/exchange) in patients with SCD.</p> </sec> <sec id="trf12891-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>Patients with SCD and a need for an RBCX procedure as part of a chronic program or as a single procedure were enrolled in this multicenter, single‐arm, open‐label study. The primary goal of the study was to confirm that the predicted percentage of the patient's original RBCs remaining at the end of the procedure (FCRp) reflects the actual cell fraction remaining, as measured by %HbS (FCRa). Secondary endpoints included ability of the SO to achieve the desired final hematocrit (Hct) and device‐related serious adverse events (SAEs).</p> </sec> <sec id="trf12891-sec-0003" sec-type="section"> <title>Results</title> <p>Seventy‐two patients 12 years of age or older were enrolled in the study; 60 were evaluable. The ratio of FCRa to FCRp after the RBCX procedure was 0.90, well within the prespecified range of 0.75 to 1.25. The SO was able to achieve the desired final Hct in<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12891-sec-0001" sec-type="section"> <title>Background</title> <p>The Spectra Optia apheresis system (SO), a blood component separator, can be used to perform red blood cell exchange (RBCX) procedures for the transfusion management of sickle cell disease (SCD) in adults and children. This study was designed to evaluate the performance of the SO RBCX protocols (exchange and depletion/exchange) in patients with SCD.</p> </sec> <sec id="trf12891-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>Patients with SCD and a need for an RBCX procedure as part of a chronic program or as a single procedure were enrolled in this multicenter, single‐arm, open‐label study. The primary goal of the study was to confirm that the predicted percentage of the patient's original RBCs remaining at the end of the procedure (FCRp) reflects the actual cell fraction remaining, as measured by %HbS (FCRa). Secondary endpoints included ability of the SO to achieve the desired final hematocrit (Hct) and device‐related serious adverse events (SAEs).</p> </sec> <sec id="trf12891-sec-0003" sec-type="section"> <title>Results</title> <p>Seventy‐two patients 12 years of age or older were enrolled in the study; 60 were evaluable. The ratio of FCRa to FCRp after the RBCX procedure was 0.90, well within the prespecified range of 0.75 to 1.25. The SO was able to achieve the desired final Hct in the evaluable population. The safety profile was favorable, and no patients had an SAE or unexpected adverse device effect or withdrew from the procedure or treatment due to an adverse event.</p> </sec> <sec id="trf12891-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The SO performed effectively and safely for both the RBCX procedure and the RBCX depletion/exchange procedure.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion. Volume 55:Issue 4(2015)
- Journal:
- Transfusion
- Issue:
- Volume 55:Issue 4(2015)
- Issue Display:
- Volume 55, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 55
- Issue:
- 4
- Issue Sort Value:
- 2015-0055-0004-0000
- Page Start:
- 775
- Page End:
- 781
- Publication Date:
- 2014-10-21
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.12891 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4082.xml