A visual grading study for different administered activity levels in bone scintigraphy. (4th May 2014)
- Record Type:
- Journal Article
- Title:
- A visual grading study for different administered activity levels in bone scintigraphy. (4th May 2014)
- Main Title:
- A visual grading study for different administered activity levels in bone scintigraphy
- Authors:
- Gustafsson, Agnetha
Karlsson, Henrik
Nilsson, Kerstin A.
Geijer, Håkan
Olsson, Anna - Abstract:
- <abstract abstract-type="main" id="cpf12155-abs-0001"> <title>Summary</title> <sec id="cpf12155-sec-0001" sec-type="section"> <title>Introduction</title> <p>The aim of the study is to assess the administered activity levels versus visual‐based image quality using visual grading regression (VGR) including an assessment of the newly stated image criteria for whole‐body bone scintigraphy.</p> </sec> <sec id="cpf12155-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>A total of 90 patients was included and grouped in three levels of administered activity: 400, 500 and 600 MBq. Six clinical image criteria regarding image quality was formulated by experienced nuclear medicine physicians. Visual grading was performed in all images, where three physicians rated the fulfilment of the image criteria on a four‐step ordinal scale. The results were analysed using VGR. A count analysis was also made where the total number of counts in both views was registered.</p> </sec> <sec id="cpf12155-sec-0003" sec-type="section"> <title>Results</title> <p>The administered activity of 600 MBq gives significantly better image quality than 400 MBq in five of six criteria (<italic>P</italic>&lt;0·05). Comparing the administered activity of 600 MBq to 500 MBq, four criteria of six show significantly better image quality (<italic>P</italic>&lt;0·05). The administered activity of 500 MBq gives no significantly better image quality than 400 Mbq (<italic>P</italic>&lt;0·05). The count<abstract abstract-type="main" id="cpf12155-abs-0001"> <title>Summary</title> <sec id="cpf12155-sec-0001" sec-type="section"> <title>Introduction</title> <p>The aim of the study is to assess the administered activity levels versus visual‐based image quality using visual grading regression (VGR) including an assessment of the newly stated image criteria for whole‐body bone scintigraphy.</p> </sec> <sec id="cpf12155-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>A total of 90 patients was included and grouped in three levels of administered activity: 400, 500 and 600 MBq. Six clinical image criteria regarding image quality was formulated by experienced nuclear medicine physicians. Visual grading was performed in all images, where three physicians rated the fulfilment of the image criteria on a four‐step ordinal scale. The results were analysed using VGR. A count analysis was also made where the total number of counts in both views was registered.</p> </sec> <sec id="cpf12155-sec-0003" sec-type="section"> <title>Results</title> <p>The administered activity of 600 MBq gives significantly better image quality than 400 MBq in five of six criteria (<italic>P</italic>&lt;0·05). Comparing the administered activity of 600 MBq to 500 MBq, four criteria of six show significantly better image quality (<italic>P</italic>&lt;0·05). The administered activity of 500 MBq gives no significantly better image quality than 400 Mbq (<italic>P</italic>&lt;0·05). The count analysis shows that none of the three levels of administrated activity fulfil the recommendations by the EANM.</p> </sec> <sec id="cpf12155-sec-0004" sec-type="section"> <title>Conclusion</title> <p>There was a significant improvement in perceived image quality using an activity level of 600 MBq compared to lower activity levels in whole‐body bone scintigraphy for the gamma camera equipment end set‐up used in this study. This type of visual‐based grading study seems to be a valuable tool and easy to implement in the clinical environment.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical physiology and functional imaging. Volume 35:Number 3(2015:May)
- Journal:
- Clinical physiology and functional imaging
- Issue:
- Volume 35:Number 3(2015:May)
- Issue Display:
- Volume 35, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2015-0035-0003-0000
- Page Start:
- 231
- Page End:
- 236
- Publication Date:
- 2014-05-04
- Subjects:
- Physiology, Pathological -- Periodicals
Diagnostic imaging -- Periodicals
612 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=cpf ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cpf.12155 ↗
- Languages:
- English
- ISSNs:
- 1475-0961
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.333520
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4307.xml