Shear bond strength of an orthodontic self‐etching adhesive after intracoronary bleaching. (20th January 2015)
- Record Type:
- Journal Article
- Title:
- Shear bond strength of an orthodontic self‐etching adhesive after intracoronary bleaching. (20th January 2015)
- Main Title:
- Shear bond strength of an orthodontic self‐etching adhesive after intracoronary bleaching
- Authors:
- Fernandes, H. O.
Santos, L. B.
Firoozmand, L. M. - Abstract:
- <abstract abstract-type="main" id="ocr12067-abs-0001"> <title>Structured Abstract</title> <sec id="ocr12067-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the effects of intracoronary bleaching on the bond strength of orthodontic brackets using self‐etching and total‐etch adhesive systems.</p> </sec> <sec id="ocr12067-sec-0002" sec-type="section"> <title>Material and Methods</title> <p>In 60 bovine incisors, a coronal lingual access was made to clean the pulp chamber and standardise the thickness of the dentine. The sample was randomly divided into four groups (each <italic>n</italic> = 15): (CT), control group, without bleaching and bonded with the total‐etch system (Transbond<sup>™</sup> XT‐3M); (CTSE), without bleaching treatment and bonded with the self‐etching system (Transbond<sup>™</sup> Plus Self‐Etching Primer‐3M); (BT), treated with 35% hydrogen peroxide for internal bleaching and bonded with the total‐etch adhesive system; and (BTSE), treated with 35% hydrogen peroxide and bonded with the self‐etching adhesive system. Shear bond strength was measured using a universal testing machine (EMIC). The adhesive remnant index (ARI) score was verified. The data were analysed using a two‐way <sc>anova</sc> and Tukey test (<italic>p</italic> &lt; 0.05).</p> </sec> <sec id="ocr12067-sec-0003" sec-type="section"> <title>Results</title> <p>Significant differences were found, and the self‐etching adhesive groups presented the highest bond strength values<abstract abstract-type="main" id="ocr12067-abs-0001"> <title>Structured Abstract</title> <sec id="ocr12067-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the effects of intracoronary bleaching on the bond strength of orthodontic brackets using self‐etching and total‐etch adhesive systems.</p> </sec> <sec id="ocr12067-sec-0002" sec-type="section"> <title>Material and Methods</title> <p>In 60 bovine incisors, a coronal lingual access was made to clean the pulp chamber and standardise the thickness of the dentine. The sample was randomly divided into four groups (each <italic>n</italic> = 15): (CT), control group, without bleaching and bonded with the total‐etch system (Transbond<sup>™</sup> XT‐3M); (CTSE), without bleaching treatment and bonded with the self‐etching system (Transbond<sup>™</sup> Plus Self‐Etching Primer‐3M); (BT), treated with 35% hydrogen peroxide for internal bleaching and bonded with the total‐etch adhesive system; and (BTSE), treated with 35% hydrogen peroxide and bonded with the self‐etching adhesive system. Shear bond strength was measured using a universal testing machine (EMIC). The adhesive remnant index (ARI) score was verified. The data were analysed using a two‐way <sc>anova</sc> and Tukey test (<italic>p</italic> &lt; 0.05).</p> </sec> <sec id="ocr12067-sec-0003" sec-type="section"> <title>Results</title> <p>Significant differences were found, and the self‐etching adhesive groups presented the highest bond strength values (CTSE=11.55 ± 2.85 MPa; BTSE=14.14 ± 2.23 MPa). The ARI scores revealed significant differences among the groups; the greater amount of remaining adhesive was observed in the CTSE group, and the lowest scores were observed in the BT group.</p> </sec> <sec id="ocr12067-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The use of the self‐etching adhesive system, even after intracoronal bleaching, presented satisfactory adhesive strength for the bonding of brackets.</p> </sec> </abstract> … (more)
- Is Part Of:
- Orthodontics and craniofacial research. Volume 18:Number 2(2015:May)
- Journal:
- Orthodontics and craniofacial research
- Issue:
- Volume 18:Number 2(2015:May)
- Issue Display:
- Volume 18, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 18
- Issue:
- 2
- Issue Sort Value:
- 2015-0018-0002-0000
- Page Start:
- 117
- Page End:
- 124
- Publication Date:
- 2015-01-20
- Subjects:
- Skull -- Growth -- Periodicals
Facial bones -- Growth -- Periodicals
Orthodontics -- Periodicals
Orthodontics, Corrective -- Periodicals
Orthodontic appliances -- Periodicals
617.51 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1601-6343 ↗
http://estar.bl.uk/cgi-bin/sciserv.pl?collection=journals&journal=16016335 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ocr.12067 ↗
- Languages:
- English
- ISSNs:
- 1601-6335
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6296.109700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3150.xml