On the signal‐to‐noise ratio efficiency and slab‐banding artifacts in three‐dimensional multislab diffusion‐weighted echo‐planar imaging. Issue 2 (19th March 2014)
- Record Type:
- Journal Article
- Title:
- On the signal‐to‐noise ratio efficiency and slab‐banding artifacts in three‐dimensional multislab diffusion‐weighted echo‐planar imaging. Issue 2 (19th March 2014)
- Main Title:
- On the signal‐to‐noise ratio efficiency and slab‐banding artifacts in three‐dimensional multislab diffusion‐weighted echo‐planar imaging
- Authors:
- Engström, Mathias
Mårtensson, Magnus
Avventi, Enrico
Skare, Stefan - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25182-sec-0001" sec-type="section"> <title>Purpose</title> <p>Three‐dimensional (3D) multislab diffusion‐weighted echo‐planar imaging (EPI) has been suggested as an alternative for high‐resolution diffusion‐weighted imaging. In this work, the key components of the sequence are investigated, optimal scan parameter settings suggested, and a signal‐to‐noise ratio (SNR) analysis, comparing 2D diffusion‐weighted EPI and 3D multislab diffusion‐weighted EPI, is performed.</p> </sec> <sec id="mrm25182-sec-0002" sec-type="section"> <title>Methods</title> <p>Slab profiles were measured using 3D multislab EPI to investigate slab profile saturation effects with respect to TR, T<sub>1</sub> and overlap between slabs. For short TR values, two methods to reduce the slab banding artifacts are proposed. Moreover, the SNR for 2D and 3D multislab (3D‐MS) DWI have been simulated for various anatomical coverages and slab thicknesses.</p> </sec> <sec id="mrm25182-sec-0003" sec-type="section"> <title>Results</title> <p>Simulated 3D multislab scans were shown to be more SNR‐efficient than a corresponding 2D scan, for all investigated anatomical coverages and slab thicknesses. Slab banding artifacts being negligible for long repetition times (TRs) were strong for a TR of 2000 ms, proving that they stem from T<sub>1</sub>‐saturation effects. This banding was largely reduced by the suggested correction<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25182-sec-0001" sec-type="section"> <title>Purpose</title> <p>Three‐dimensional (3D) multislab diffusion‐weighted echo‐planar imaging (EPI) has been suggested as an alternative for high‐resolution diffusion‐weighted imaging. In this work, the key components of the sequence are investigated, optimal scan parameter settings suggested, and a signal‐to‐noise ratio (SNR) analysis, comparing 2D diffusion‐weighted EPI and 3D multislab diffusion‐weighted EPI, is performed.</p> </sec> <sec id="mrm25182-sec-0002" sec-type="section"> <title>Methods</title> <p>Slab profiles were measured using 3D multislab EPI to investigate slab profile saturation effects with respect to TR, T<sub>1</sub> and overlap between slabs. For short TR values, two methods to reduce the slab banding artifacts are proposed. Moreover, the SNR for 2D and 3D multislab (3D‐MS) DWI have been simulated for various anatomical coverages and slab thicknesses.</p> </sec> <sec id="mrm25182-sec-0003" sec-type="section"> <title>Results</title> <p>Simulated 3D multislab scans were shown to be more SNR‐efficient than a corresponding 2D scan, for all investigated anatomical coverages and slab thicknesses. Slab banding artifacts being negligible for long repetition times (TRs) were strong for a TR of 2000 ms, proving that they stem from T<sub>1</sub>‐saturation effects. This banding was largely reduced by the suggested correction methods.</p> </sec> <sec id="mrm25182-sec-0004" sec-type="section"> <title>Conclusion</title> <p>In the low TR regime, T<sub>1</sub>‐saturation effects between adjacent slabs need to be taken in consideration to avoid slab‐banding artifacts for multislab sequences. With the proposed correction methods the difference between the SNR‐optimal TR and the TR where slab‐banding artifacts become acceptable is reduced. <bold>Magn Reson Med 73:718–725, 2015. © 2014 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 2(2015:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 2(2015:Feb.)
- Issue Display:
- Volume 73, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 2
- Issue Sort Value:
- 2015-0073-0002-0000
- Page Start:
- 718
- Page End:
- 725
- Publication Date:
- 2014-03-19
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25182 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3334.xml