On the accuracy of T1 mapping: Searching for common ground. Issue 2 (27th February 2014)
- Record Type:
- Journal Article
- Title:
- On the accuracy of T1 mapping: Searching for common ground. Issue 2 (27th February 2014)
- Main Title:
- On the accuracy of T1 mapping: Searching for common ground
- Authors:
- Stikov, Nikola
Boudreau, Mathieu
Levesque, Ives R.
Tardif, Christine L.
Barral, Joëlle K.
Pike, G. Bruce - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25135-sec-0001" sec-type="section"> <title>Purpose</title> <p>There are many T<sub>1</sub> mapping methods available, each of them validated in phantoms and reporting excellent agreement with literature. However, values in literature vary greatly, with T<sub>1</sub> in white matter ranging from 690 to 1100 ms at 3 Tesla. This brings into question the accuracy of one of the most fundamental measurements in quantitative MRI. Our goal was to explain these variations and look into ways of mitigating them.</p> </sec> <sec id="mrm25135-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>We evaluated the three most common T<sub>1</sub> mapping methods (inversion recovery, Look‐Locker, and variable flip angle) through Bloch simulations, a white matter phantom and the brains of 10 healthy subjects (single‐slice). We pooled the T<sub>1</sub> histograms of the subjects to determine whether there is a sequence‐dependent bias and whether it is reproducible across subjects.</p> </sec> <sec id="mrm25135-sec-0003" sec-type="section"> <title>Results</title> <p>We found good agreement between the three methods in phantoms, but poor agreement in vivo, with the white matter T<sub>1</sub> histogram peak in healthy subjects varying by more than 30% depending on the method used. We also found that the pooled brain histograms displayed three distinct white matter peaks, with Look‐Locker<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25135-sec-0001" sec-type="section"> <title>Purpose</title> <p>There are many T<sub>1</sub> mapping methods available, each of them validated in phantoms and reporting excellent agreement with literature. However, values in literature vary greatly, with T<sub>1</sub> in white matter ranging from 690 to 1100 ms at 3 Tesla. This brings into question the accuracy of one of the most fundamental measurements in quantitative MRI. Our goal was to explain these variations and look into ways of mitigating them.</p> </sec> <sec id="mrm25135-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>We evaluated the three most common T<sub>1</sub> mapping methods (inversion recovery, Look‐Locker, and variable flip angle) through Bloch simulations, a white matter phantom and the brains of 10 healthy subjects (single‐slice). We pooled the T<sub>1</sub> histograms of the subjects to determine whether there is a sequence‐dependent bias and whether it is reproducible across subjects.</p> </sec> <sec id="mrm25135-sec-0003" sec-type="section"> <title>Results</title> <p>We found good agreement between the three methods in phantoms, but poor agreement in vivo, with the white matter T<sub>1</sub> histogram peak in healthy subjects varying by more than 30% depending on the method used. We also found that the pooled brain histograms displayed three distinct white matter peaks, with Look‐Locker consistently underestimating, and variable flip angle overestimating the inversion recovery T<sub>1</sub> values. The Bloch simulations indicated that incomplete spoiling and inaccurate B<sub>1</sub> mapping could account for the observed differences.</p> </sec> <sec id="mrm25135-sec-0004" sec-type="section"> <title>Conclusion</title> <p>We conclude that the three most common T<sub>1</sub> mapping protocols produce stable T<sub>1</sub> values in phantoms, but not in vivo. To improve the accuracy of T<sub>1</sub> mapping, we recommend that sites perform in vivo validation of their T<sub>1</sub> mapping method against the inversion recovery reference method, as the first step toward developing a robust calibration scheme. <bold>Magn Reson Med 73:514–522, 2015. © 2014 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 73:Issue 2(2015:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 73:Issue 2(2015:Feb.)
- Issue Display:
- Volume 73, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 73
- Issue:
- 2
- Issue Sort Value:
- 2015-0073-0002-0000
- Page Start:
- 514
- Page End:
- 522
- Publication Date:
- 2014-02-27
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25135 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3333.xml