A randomized trial on the aesthetic outcomes of implant‐supported restorations with zirconia or titanium abutments. (21st November 2014)
- Record Type:
- Journal Article
- Title:
- A randomized trial on the aesthetic outcomes of implant‐supported restorations with zirconia or titanium abutments. (21st November 2014)
- Main Title:
- A randomized trial on the aesthetic outcomes of implant‐supported restorations with zirconia or titanium abutments
- Authors:
- Carrillo de Albornoz, Ana
Vignoletti, Fabio
Ferrantino, Luca
Cárdenas, Eduardo
De Sanctis, Massimo
Sanz, Mariano - Abstract:
- <abstract abstract-type="main" id="jcpe12312-abs-0001"> <title>Abstract</title> <sec id="jcpe12312-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate the aesthetic outcomes of zirconia <italic>versus</italic> titanium abutments for single tooth implant‐supported crowns in the anterior maxilla.</p> </sec> <sec id="jcpe12312-sec-0002" sec-type="section"> <title>Material &amp; Methods</title> <p>A parallel, double blind clinical trial was conducted at the Complutense University (Madrid), where 38 patients were recruited. After random allocation (via computer‐generated permuted blocks), either zirconia (test) or titanium (control) abutments were placed. Intra‐ and inter‐group differences in aesthetic (main outcome), clinical, radiographical, and patient‐centred outcomes were evaluated at baseline (crown placement) and at 1‐year follow‐up.</p> </sec> <sec id="jcpe12312-sec-0003" sec-type="section"> <title>Results</title> <p>At 1 year, 25 of the 30 randomized patients were analysed (11 test and 14 control). Using the Implant Crown Aesthetic Index (ICAI), the scoring at baseline and 1‐year were 7.9 and 7.6 for the test group and 10.6 and 11.3 for the control group, respectively. These differences were not statistically significant (sample size non‐contrasted). Patient satisfaction was similarly high in both groups (visual analogue scale 8.5). Furthermore, no differences were observed in the clinical or radiographical outcomes. Two abutment fractures were registered in<abstract abstract-type="main" id="jcpe12312-abs-0001"> <title>Abstract</title> <sec id="jcpe12312-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate the aesthetic outcomes of zirconia <italic>versus</italic> titanium abutments for single tooth implant‐supported crowns in the anterior maxilla.</p> </sec> <sec id="jcpe12312-sec-0002" sec-type="section"> <title>Material &amp; Methods</title> <p>A parallel, double blind clinical trial was conducted at the Complutense University (Madrid), where 38 patients were recruited. After random allocation (via computer‐generated permuted blocks), either zirconia (test) or titanium (control) abutments were placed. Intra‐ and inter‐group differences in aesthetic (main outcome), clinical, radiographical, and patient‐centred outcomes were evaluated at baseline (crown placement) and at 1‐year follow‐up.</p> </sec> <sec id="jcpe12312-sec-0003" sec-type="section"> <title>Results</title> <p>At 1 year, 25 of the 30 randomized patients were analysed (11 test and 14 control). Using the Implant Crown Aesthetic Index (ICAI), the scoring at baseline and 1‐year were 7.9 and 7.6 for the test group and 10.6 and 11.3 for the control group, respectively. These differences were not statistically significant (sample size non‐contrasted). Patient satisfaction was similarly high in both groups (visual analogue scale 8.5). Furthermore, no differences were observed in the clinical or radiographical outcomes. Two abutment fractures were registered in the test group.</p> </sec> <sec id="jcpe12312-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The use of zirconia abutments demonstrated a tendency towards better aesthetic outcomes although the differences were not statistically significant. However, more technical complications were noted with the use of zirconia abutments.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical periodontology. Volume 41:Number 12(2014:Dec.)
- Journal:
- Journal of clinical periodontology
- Issue:
- Volume 41:Number 12(2014:Dec.)
- Issue Display:
- Volume 41, Issue 12 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 12
- Issue Sort Value:
- 2014-0041-0012-0000
- Page Start:
- 1161
- Page End:
- 1169
- Publication Date:
- 2014-11-21
- Subjects:
- Periodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cpe ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-051X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jcpe.12312 ↗
- Languages:
- English
- ISSNs:
- 0303-6979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.672000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3523.xml