Rapid detection and isotopic measurement of discrete inorganic samples using acoustically actuated droplet ejection and extractive electrospray ionization mass spectrometry. (15th January 2015)
- Record Type:
- Journal Article
- Title:
- Rapid detection and isotopic measurement of discrete inorganic samples using acoustically actuated droplet ejection and extractive electrospray ionization mass spectrometry. (15th January 2015)
- Main Title:
- Rapid detection and isotopic measurement of discrete inorganic samples using acoustically actuated droplet ejection and extractive electrospray ionization mass spectrometry
- Authors:
- Forbes, Thomas P.
- Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm7074-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>The rapid detection, screening, and isotopic signature analysis of inorganics provide invaluable information for a variety of applications including explosive device detection, nuclear forensics, and environmental monitoring. The coupling of ultrasonic nebulization and extractive electrospray ionization (EESI) enabled the mass spectrometric (MS) detection and analysis of inorganics from microliter sample solution aliquots.</p> </sec> <sec id="rcm7074-sec-0002" sec-type="section"> <title>METHODS</title> <p>Ultrasonic nebulization and acoustic pressure wave focusing within an array of exponential horn structures were utilized for the efficient atomization of discrete liquid samples ranging in volume from 3 μL to 10 μL pipetted aliquots. In conjunction with an electro‐flow focusing source for extractive electrospray ionization (EESI), in‐source collision‐induced dissociation (CID) was utilized to enhance inorganic detection through fragmentation of adducts and reduction in chemical noise from organic compounds.</p> </sec> <sec id="rcm7074-sec-0003" sec-type="section"> <title>RESULTS</title> <p>The investigated system enhanced detection of the singly charged elemental cation species and provided accurate measurements of isotopic distributions for a number of metal ions. The extent of CID demonstrated the competition<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm7074-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>The rapid detection, screening, and isotopic signature analysis of inorganics provide invaluable information for a variety of applications including explosive device detection, nuclear forensics, and environmental monitoring. The coupling of ultrasonic nebulization and extractive electrospray ionization (EESI) enabled the mass spectrometric (MS) detection and analysis of inorganics from microliter sample solution aliquots.</p> </sec> <sec id="rcm7074-sec-0002" sec-type="section"> <title>METHODS</title> <p>Ultrasonic nebulization and acoustic pressure wave focusing within an array of exponential horn structures were utilized for the efficient atomization of discrete liquid samples ranging in volume from 3 μL to 10 μL pipetted aliquots. In conjunction with an electro‐flow focusing source for extractive electrospray ionization (EESI), in‐source collision‐induced dissociation (CID) was utilized to enhance inorganic detection through fragmentation of adducts and reduction in chemical noise from organic compounds.</p> </sec> <sec id="rcm7074-sec-0003" sec-type="section"> <title>RESULTS</title> <p>The investigated system enhanced detection of the singly charged elemental cation species and provided accurate measurements of isotopic distributions for a number of metal ions. The extent of CID demonstrated the competition between ligand loss from hydrate clusters and charge reduction from the doubly charged to singly charged cations for the alkaline earth metal ions of strontium and barium. Inorganics were also detected from complex matrices, including synthetic fingerprint material and sediment, without detriment to device operation.</p> </sec> <sec id="rcm7074-sec-0004" sec-type="section"> <title>CONCLUSIONS</title> <p>The described system provides a versatile tool for the rapid detection, speciation, and isotopic identification of inorganic compounds at nanogram to sub‐nanogram levels from microliter aliquots. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.</p> </sec> </abstract> … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 29:Number 1(2015)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 29:Number 1(2015)
- Issue Display:
- Volume 29, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 1
- Issue Sort Value:
- 2015-0029-0001-0000
- Page Start:
- 19
- Page End:
- 28
- Publication Date:
- 2015-01-15
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7074 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3896.xml