Positive contrast of SPIO‐labeled cells by off‐resonant reconstruction of 3D radial half‐echo bSSFP. (7th November 2014)
- Record Type:
- Journal Article
- Title:
- Positive contrast of SPIO‐labeled cells by off‐resonant reconstruction of 3D radial half‐echo bSSFP. (7th November 2014)
- Main Title:
- Positive contrast of SPIO‐labeled cells by off‐resonant reconstruction of 3D radial half‐echo bSSFP
- Authors:
- Diwoky, Clemens
Liebmann, Daniel
Neumayer, Bernhard
Reinisch, Andreas
Knoll, Florian
Strunk, Dirk
Stollberger, Rudolf - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>This article describes a new acquisition and reconstruction concept for positive contrast imaging of cells labeled with superparamagnetic iron oxides (SPIOs). Overcoming the limitations of a negative contrast representation as gained with gradient echo and fully balanced steady state (bSSFP), the proposed method delivers a spatially localized contrast with high cellular sensitivity not accomplished by other positive contrast methods. Employing a 3D radial bSSFP pulse sequence with half‐echo sampling, positive cellular contrast is gained by adding artificial global frequency offsets to each half‐echo before image reconstruction. The new contrast regime is highlighted with numerical intravoxel simulations including the point‐spread function for 3D half‐echo acquisitions. Furthermore, the new method is validated on the basis of <italic>in vitro</italic> cell phantom measurements on a clinical MRI platform, where the measured contrast‐to‐noise ratio (CNR) of the new approach exceeds even the negative contrast of bSSFP. Finally, an <italic>in vivo</italic> proof of principle study based on a mouse model with a clear depiction of labeled cells within a subcutaneous cell islet containing a cell density as low as 7 cells/mm<sup>3</sup> is presented. The resultant isotropic images show robustness to motion and a high CNR, in addition to an enhanced specificity due to the positive contrast of<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>This article describes a new acquisition and reconstruction concept for positive contrast imaging of cells labeled with superparamagnetic iron oxides (SPIOs). Overcoming the limitations of a negative contrast representation as gained with gradient echo and fully balanced steady state (bSSFP), the proposed method delivers a spatially localized contrast with high cellular sensitivity not accomplished by other positive contrast methods. Employing a 3D radial bSSFP pulse sequence with half‐echo sampling, positive cellular contrast is gained by adding artificial global frequency offsets to each half‐echo before image reconstruction. The new contrast regime is highlighted with numerical intravoxel simulations including the point‐spread function for 3D half‐echo acquisitions. Furthermore, the new method is validated on the basis of <italic>in vitro</italic> cell phantom measurements on a clinical MRI platform, where the measured contrast‐to‐noise ratio (CNR) of the new approach exceeds even the negative contrast of bSSFP. Finally, an <italic>in vivo</italic> proof of principle study based on a mouse model with a clear depiction of labeled cells within a subcutaneous cell islet containing a cell density as low as 7 cells/mm<sup>3</sup> is presented. The resultant isotropic images show robustness to motion and a high CNR, in addition to an enhanced specificity due to the positive contrast of SPIO‐labeled cells. Copyright © 2014 John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- NMR in biomedicine. Volume 28:Number 1(2015:Jan.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 28:Number 1(2015:Jan.)
- Issue Display:
- Volume 28, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2015-0028-0001-0000
- Page Start:
- 79
- Page End:
- 88
- Publication Date:
- 2014-11-07
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3229 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3763.xml